3. Connecting with the Controller
32
3. Connecting with the Controller
As the connection cable for the controller and RCS3 (this actuator), use the IAI-dedicated controller and
dedicated connection cable.
This section explains the wiring method for a single axis.
• If the dedicated connection cable cannot be secured, reduce the load on the cable by allowing it to
deflect only by the weight of the cable or wire it in a self-standing cable hose, etc., having a large
radius.
• Do not cut and reconnect the dedicated connection cable for extension or shorten the cable.
• Do not pull on the dedicated connection cable or bend it forcibly.
• The actuator cable coming out of the motor unit is not meant to be bent. Fix the cable so it would not
be bent repeatedly
Please consult with IAI if you require a different kind of cable than the one supplied.
RCP5(CR)-XX
MSEP
RCP5-XX
MSEL
Dedicated Controller
Dedicated connection cable
Dedicated connection cable
(Connect RCP5 with the dedicated controller)
Robot cable
: 5m or less
r=68mm or more (Movable use)
: 5m then longer cases r=73mm or more (Movable use)
Standard cable
: 5m or less
r=85mm or more (Fixed use)
: 5m then longer cases r=91mm or more (Fixed use)
Motor • encoder cables: CB-CAN-MPA□□□
Motor • encoder cables robot type: CB-CAN-MPA□□□-RB
(Note) □□□ indicates the cable length. Up to 20m can be specified.
Example) 080=8m