1. Specifications Check
13
1.2 Specifications
1.2.1 Speed
[When high-output setting is effective]
Speed limits [Unit: mm/s]
Stroke [mm]
Size Motor
Type
Lead
[mm] 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900
BA4
BA4U 35P
48 or
equiv. 890 1040 1120 1160
1200
-
-
-
-
-
-
-
BA6
BA6U 42P
48 or
equiv. 890 1070 1220 1340 1400 1440
1500
BA7
BA7U 56P
48 or
equiv. 890 1070 1220 1340 1450 1520 1550
1600
Stroke [mm]
Size Motor
Type
Lead
[mm] 2000 2100 2200 2300 2400 2500 2600
BA4
BA4U 35P
48 or
equiv. -
-
-
-
-
-
-
BA6
BA6U 42P
48 or
equiv.
1500
-
-
-
-
BA7
BA7U 56P
48 or
equiv.
1600
Caution: Use the unit with velocity at 100mm/s or more (150mm/s or more for BA4/4U).
Operation with 100mm/s or less (150mm/s or less for BA4/4U) may cause vibration
or noise.