1. Specifications Check
20
1.3 Options
1.3.1 Brake Type (Model: B)
This is a feature to retain the slider so it would not move when the power or servo is turned OFF.
1.3.2 Reversed-home Specification (Model: NM)
The standard home position is on the motor side. However, the motor position will be reversed if it is
desirable in view of the layout of the system, etc.
(Note) The home position is adjusted at the factory before shipment. If you wish to change the home
after the delivery of your actuator, you must return the actuator to IAI for adjustment.
1.3.3 Cable Eject Direction Changed (Model: CJT, CJR, CJL, CJB)
If a change in the cable ejection direction is made, the direction of cable ejection will be changed.
There are ejection directions, top (model: CJT), right (model: CJR), left (model: CJL) and bottom (model:
CJB).
It is necessary to select either of CJT, CJR, CJL or CJB for this option.
1.3.4 Ceiling Mount Type (Model: CIM), Left Horizontally Oriented Wall Mount Type
(Model: SIL) and Right Horizontally Oriented Wall Mount Type (Model: SIR).
It is an option that the actuator is adjusted so it can be installed in ceiling mount, horizontally oriented
wall mount with the motor unit on the left or horizontally oriented wall mount with the motor unit on the
right. The model codes are ceiling mount type (model: CIM), left horizontally oriented wall mount type
(model: SIL) and right horizontally oriented wall mount type (model: SIR).
(Note) Standard horizontal orientation type and ceiling mount type cannot be installed in horizontally
oriented wall mount. Also, horizontally oriented wall mount type cannot be installed in standard
horizontal orientation or ceiling mount.
[Left and Right Horizontally Oriented Wall Mount Types]
Left horizontally oriented wall mount type
Right horizontally oriented wall mount type
(model: SIL)
(model: SIR)
Bottom
Top
CJT
CJR
CJL
CJB
Motor unit
Motor unit
Bottom
Top
Bottom
Top