![IAI ELECYLINDER EC-WS10 R Series Скачать руководство пользователя страница 12](http://html1.mh-extra.com/html/iai/elecylinder-ec-ws10-r-series/elecylinder-ec-ws10-r-series_manual_3247857012.webp)
EC-WS12
EC-DWS12
<With digital speed controller>
■
Model Specification Items
EC
-
-
-
-
Series
-
Type
Lead
-
Stroke
-
Power •
I/O cable length
-
Options
WS12
Standard
S
24mm
50
50mm
See power
•
I/O cable length
below
See options
below
DWS12
Digital speed controller
H
16mm
~
~
M
8mm
800
800mm
L
4mm
(Every 50mm)
デジタルスピコン
■
Stroke
Stroke
(mm)
WS12
DWS12
Stroke
(mm)
WS12
DWS12
50
450
100
500
150
550
200
600
250
650
300
700
350
750
400
800
■
Options
(Note 1) If the RCON-EC connection specification (ACR) is selected, the PNP specification
(PN) and split motor and controller power supply specification (TMD2) cannot be
selected.
(Note 2) Available only for DWS12. Be sure to enter a model in the options section of the
model number.
■
Power · I/O cable length
■
Standard connector cable
Cable code
Cable
length
User wiring specification
(flying leads)
RCON-EC connection specification (Note 4)
(with connectors on both ends)
CB-EC-PWBIO
£££
-RB
supplied
CB-REC-PWBIO
£££
-RB
supplied
0
No cable
(Note 3)
1 ~ 3
1 ~ 3m
4 ~ 5
4 ~ 5m
6 ~ 7
6 ~ 7m
8 ~ 10
8 ~ 10m
(Note 3) Only terminal block connector is included. Please refer to P. 31 for details.
(Note 4) If RCON-EC connection specification (ACR) is selected as an option.
(Note) Robot cable is standard.
■
4-way connector cable
Cable code
Cable
length
User wiring specification
(flying leads)
RCON-EC connection specification (Note 5)
(with connectors on both ends)
CB-EC2-PWBIO
£££
-RB
supplied
CB-REC2-PWBIO
£££
-RB
supplied
S1 ~ S3
1 ~ 3m
S4 ~ S5
4 ~ 5m
S6 ~ S7
6 ~ 7m
S8 ~ S10
8 ~ 10m
(Note 5) If RCON-EC connection specification (ACR) is selected as an option.
(Note) Robot cable is standard.
24
V
Stepper
Motor
Body Width
120
mm
Coupled
Motor
Simple
Dust-
proof
Horizontal
Ver
tical
Side
Ceiling
EC-WS12/DWS12
Name
Option code
Reference page
RCON-EC connection specification (Note 1)
ACR
23
Brake
B
23
Air cylinder mounting plate
CS
23
Digital speed controller installation direction (left) (Note 2)
DL
24
Digital speed controller installation direction (right) (Note 2)
DR
24
Designated grease specification
G1/G5
25
Non-motor end specification
NM
25
PNP specification
PN
25
Slider part roller specification
SR
25
Split motor and controller power supply specification
TMD2
25
Battery-less
absolute encoder specification
WA
25
Wireless communication specification
WL
25
Wireless axis operation specification
WL2
25
Selection
Notes
(1) The maximum speed decreases as the stroke becomes longer
due to the dangerous number of rotation of the ball screw.
Confirm the maximum speed, referring to the “Stroke and Max.
Speed” of the desired stroke.
(2) “Main Specifications” displays the payload’s maximum value. If
the energy-saving setting is enabled, the main specifications will
change. Please refer to “Table of Payload by Speed/Acceleration”
for details.
(3) If performing push-motion operations, refer to the “Correlation
between Torque and Current Limit” diagram. The torques listed
are only reference values. Refer to P. 26 for precautions.
(4) The duty ratio is to be limited depending on the ambient
operating temperature. Refer to P. 26 for precautions.
(5) Pay close attention to the installation orientation.
Please refer to P. 5 for details.
(6) The “H” and “S” leads cannot be vertically mounted.
(7) Push-motion operations are unavailable for the “S” lead.
(8) Reference value of the overhang load length is under 400mm in
the Ma, Mb, and Mc directions. Refer to descriptions about the
overhang length on P. 5.
(8) The center of gravity of the attached object should be less than
1/2 of the overhang distance. Even when the overhang distance
and load moment are within the allowable range, the operating
conditions should be moderated if some abnormal vibration or
noise is observed.
Digital speed controller
EC-WS12
EC-DWS12
11
EC
ELECYLINDER
®
Содержание ELECYLINDER EC-WS10 R Series
Страница 1: ...www intelligentactuator com...