3.5 Wiring connections (for cables)
3-13
3. Wiring
PLC wiring
For I/O between the PLC and signals, the wiring of the power I/O cable must
be connected to the PLC.
Connect the to wiring to the PLC terminal block while referring to
the connection diagram.
Connect the [orange] cable wire and the [Backward] output terminal.
Connect the [yellow] cable wire and the [Forward] output terminal.
Connect the [green] cable wire and the [Alarm clear] output terminal.
Connect the [blue] cable wire and the [Backward complete] input terminal.
Connect the [purple] cable wire and the [Forward complete] input terminal.
Connect the [gray] cable wire and the [Alarm] input terminal.
3
8
PLC connection
3
4
5
6
7
8
PLC
Process the terminals
in accordance with
PLC specifications
in order to conduct
wiring.
Enlarged view of power I/O
cable connector terminal section
ELECYLINDER/Power I/O cable
Содержание EC-RR6*AH series
Страница 9: ......
Страница 28: ...Intro 19...
Страница 130: ...1 100 1 Specifications...
Страница 183: ...2 6 Installation of radial cylinder type 2 51 2 Installation Oscillation receiving bracket movable range NJPB QRPB...
Страница 199: ...2 7 Installation of high rigidity radial cylinder type 2 67 2 Installation For EC RR7 AH and EC RR7 H...
Страница 202: ...2 70 2 Installation...
Страница 218: ...3 15 3 Wiring...
Страница 240: ...4 21 4 Operation...
Страница 315: ...9 1 Slider type 9 2 9 External Dimensions EC S7 M E Mechanical end S E Stroke end ST Stroke Unit mm...
Страница 321: ...9 4 Rod type 9 8 9 External Dimensions EC R7 M E Mechanical end S E Stroke end ST Stroke Unit mm...
Страница 323: ...9 5 Radial cylinder type 9 10 9 External Dimensions EC RR7 M E Mechanical end S E Stroke end ST Stroke Unit mm...
Страница 328: ...9 15 9 External Dimensions...
Страница 336: ...11 3 11 Warranty...
Страница 337: ...Appendix 12 1 Index 12 1 12 2 Revision history 12 7 ELECYLINDER Chapter12...
Страница 346: ......
Страница 347: ......