Safety Guide
Intro-6
No. Operation
Precautions
6 Trial
Operation
●
When working with two or more persons, make it clear who is to be in charge
and communicate well with each other to ensure safety.
●
After teaching or programming, carry out trial operation step by step before
switching to automatic operation.
●
When trial operation is to be performed inside the safety/protection fence, use
the same work procedure, determined in advance, as teaching operation.
●
Be sure to confirm program operation at safe speeds. Otherwise, this may
lead to accidents due to unexpected motion caused by program error, etc.
●
Do not touch the terminal block or any of the various setting switches while the
equipment is live. Otherwise, this may lead to electric shock or abnormal
operation.
7 Automatic
Operation
●
Check before starting automatic operation or restarting after operation stop
that there is nobody within the safety/protection fence.
●
Before starting automatic operation, make sure that all peripheral equipment
is ready for automatic operation and that there is no alarm indication.
●
Be sure to start automatic operation from outside the safety/protection fence.
●
If the product produces abnormal heat, smoke, odor, or noise, immediately
stop it and turn OFF the power switch. Otherwise, this may lead to fire or
damage to the product.
●
When a power failure occurs, turn OFF the power switch. Otherwise, this may
lead to injury or product damage due to unexpected product motion during
recovery from the power failure.
8 Maintenance
and
Inspection
●
When working with two or more persons, make it clear who is to be in charge
and communicate well with each other to ensure safety.
●
Perform the work outside the safety/protection fence, if possible. If operation
must be performed within the safety/protection fence, prepare "Work
Regulations" and make sure that all the workers acknowledge and
understand them well.
●
When work is to be performed inside the safety/protection fence, turn OFF the
power switch as a rule.
●
When operation is to be performed inside the safety/protection fence,
operators should have emergency stop switches available at hand so that the
unit can be stopped at any time if abnormalities occur.
●
When operation is to be performed inside the safety/protection fence, have a
monitor standing by in addition to the operator(s) so that the unit can be
stopped at any time if abnormalities occur. Also, keep watch on the operation
so that a third party cannot operate the switches carelessly.
●
Place a sign indicating "Operating" where it can be seen easily.
●
For the grease for the guide or ball screw, use appropriate grease according
to the Instruction Manual for each model.
●
Do not perform dielectric strength testing. Otherwise, this may lead to damage
to the product.
Содержание EC-RR6*AH series
Страница 9: ......
Страница 28: ...Intro 19...
Страница 130: ...1 100 1 Specifications...
Страница 183: ...2 6 Installation of radial cylinder type 2 51 2 Installation Oscillation receiving bracket movable range NJPB QRPB...
Страница 199: ...2 7 Installation of high rigidity radial cylinder type 2 67 2 Installation For EC RR7 AH and EC RR7 H...
Страница 202: ...2 70 2 Installation...
Страница 218: ...3 15 3 Wiring...
Страница 240: ...4 21 4 Operation...
Страница 315: ...9 1 Slider type 9 2 9 External Dimensions EC S7 M E Mechanical end S E Stroke end ST Stroke Unit mm...
Страница 321: ...9 4 Rod type 9 8 9 External Dimensions EC R7 M E Mechanical end S E Stroke end ST Stroke Unit mm...
Страница 323: ...9 5 Radial cylinder type 9 10 9 External Dimensions EC RR7 M E Mechanical end S E Stroke end ST Stroke Unit mm...
Страница 328: ...9 15 9 External Dimensions...
Страница 336: ...11 3 11 Warranty...
Страница 337: ...Appendix 12 1 Index 12 1 12 2 Revision history 12 7 ELECYLINDER Chapter12...
Страница 346: ......
Страница 347: ......