39
Example 3:
Relative Coordinates pitch movement 30 mm
→
40 mm
→
50 mm….
Operation
Screen
Reference
1. Press the
key.
2. Press the
key to select
“MDI.”
3.
Set 0 into the position No. with
the
or
key.
For any unregistered data, the
display will show “*” sign.
4.
Move the cursor to the “Pos” input
position with the
,
,
or
key.
5. Input
here, and then
press the Return key.
In order to stop during numeric
input, press the
key to
cancel the input.
Example) With the left operation,
by pressing
immediately
after inputting
, the
status will return to the “*” display.
6.
During new position data
registration, the initial values set
with the user parameters for Vel,
Acc, Dcc, etc., will automatically
be input.
In the left screen, the initial value
is set as 100 mm/sec.