
47
5) Inching
(Method: Incremental movement using arrow key, matching to the desired position and teaching that
position into the position table)
If you press the JOG- and JOG+ key once, the actuator will move by a specified pitch.
If you continue pressing the arrow key, the actuator will move by jogging at 1 mm/sec. The speed will
increase every one second. Finer movement than jogging is possible.
When inching movement is performed first after power-on, it is required to perform home return operation in
advance. (Refer to page 32.) (Increment specification)
Caution:
Operating instructions are described on the screens of PCON, ACON and SCON.
Example:
2 point continuous loop Point A --> Point B, speed 300mm/sec
Operation
Screen
Reference
1. Press the
key.
2. Press the
key to select
“Teach/Play.”
3. Press the
key to select
“Inching.”
4.
Input the desired inching distance
with the ten keys and press the
Return key.
The input range is from 0.01 mm
to 1.00 mm.
5. Move the slider with the
and
key and match to the
desired position.
6. Press the
key.
Содержание CON-T
Страница 1: ...Teaching Pendant Operating Manual First edition IAI America Inc ...
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 14: ...6 6 2 External View External Dimensions ...
Страница 78: ...70 Examples of PCON CY Controller On following page ...
Страница 79: ...71 From previous page On following page ...
Страница 80: ...72 From previous page On following page ...
Страница 81: ...73 From previous page ...
Страница 95: ......