31
—
AP-
16
00T-
PMCL
Calculate the H_Period using the following formulas when cutting out a portion of the
image using ROI.
H_Count = Max(Sensor_H_Max, CL_H_Count_Max)
H_Period = H_Count × Binning_vert / 74.25MHz
Binning_vert = 1 : Vertical Binning is Off
Binning_vert = 2 : Vertical Binning is On
The Sensor_H_Max values and Pack Value are as follows for each ClConfiguration,
PixelFormat and CameraLink Clock Frequency.
Base/RGB8
846
846
846
Medium/RGB8
846
846
846
Medium/RGB10
846
846
846
Medium/RGB12
846
846
846
Full/RGB8
846
846
846
EightyBit/RGB8
846
846
846
37.125MHz
74.25 MHz
84.86 MHz
37.125MHz
74.25 MHz
84.86 MHz
37.125MHz
74.25 MHz
84.86 MHz
37.125MHz
74.25 MHz
84.86 MHz
37.125MHz
74.25 MHz
84.86 MHz
37.125MHz
74.25 MHz
84.86 MHz
ClConfiguration/
PixelFormat
CameraLink Clock
Frequency
Sensor_H_Max
Calculate the CL_H_Count_Max using the following formulas.
CL_H_Count_Max =
Roundup( (Width / Pack Value) + 4 ) × 74.25MHz / CameraLink Clock Frequency, 0 )
1
1
1
2
2
2
1
1
1
1
1
1
8/3
(2.667)
Pack Value
8/3
(2.667)
8/3
(2.667)
10/3
(3.333)
10/3
(3.333)
10/3
(3.333)