64
—
AP-3200T-
PMCL
Item
Setting range
Default value
Description
o) JAICustomControlALC
Configure JAI ALC settings. These
settings are also used for AGC (auto
gain control).
ALCReference
30 to 95
50
Set the target level for ALC. (unit:
%)
ALCAreaSelector
LowRight,
LowMid-Right,
LowMid-Left,
LowLeft,
Mid-LowRight,
Mid-LowMid-Right,
Mid-LowMid-Left,
Mid-LowLeft,
Mid-HighRight,
Mid-HighMid-Right,
Mid-HighMid-Left,
Mid-HighLeft,
HighRight,
HighMid-Right,
HighMid-Left,
HighLeft
Low Right
Select the area for which to
configure [ALCAreaEnable].
ALCAreaEnable
True, False
False
Enable/disable the photometry area
selected in [ALCAreaSelector].
ALCAreaEnableAll
True, False
True
On: Operate ALC with all areas
designated as photometry
areas, regardless of the
individual enabled/disabled
photometry area states
configured in
[ALCAreaSelector].
Off: Operate ALC according to the
individual enabled/disabled
photometry area states
configured in
[ALCAreaSelector].
AutoShutterControl
ExposureMin
100 to 13426
100
Set the minimum value for the
ExposureAuto(ASC) control range.
AutoShutterControl
ExposueMax
101 to 13427
–
Set the maximum value for the
ExposureAuto(ASC) control range.
AutoGainControlGainRaw
Min
100 to 1599
100
Set the minimum value for the
GainAuto(ASC) control range.
AutoGainControlGainRaw
Max
101 to 800
800
Set the maximum value for the
GainAuto(ASC) control range.
ALCControlSpeed
1 (slow) to 8 (fast)
4
Set the response speed for AGC/
ASC. (8 is the fastest.)
ALCStatus
Off, ASC, AGC
–
Allows confirmation of the current
operation area during ALC
operation.
AutoControlStatus
ExecutingASC,
ExecutingAGC,
ExecutingASCandAGC,
ExecutingAWB,
ExecutingASCandAWB,
ExecutingAGCandAWB,
ExecutingASCandAGCand
AWB,
Convergen,
Idle
–
Allows confirmation of the AGC,