background image

Contents

— 2 —

AP-3200T-

PMCL

Notice ..........................................................3

Warranty ......................................................3

Certifications ................................................3

Warning .......................................................3

Usage Precautions ........................................5

Features .......................................................6

Parts Identification .......................................7

Preparation ............................................ 11

Preparation Process....................................11

Step 1: Installing the Software (first time 

only) ..........................................................11

Step 2: Connecting Devices ........................12

Step 3: Verifying Camera Operation ............14

Step 4: Verifying the Connection between the 

Camera and PC ...........................................14

Connecting the Camera to Control Tool .........14

Step 5: Changing the Camera Settings ........

18

Configuring the Output Format ....................18

Step 6: Adjusting the Image Quality ...........

20

Displaying the Image .................................20

Adjusting the Gain .....................................20

Manual adjustment .................................20

Adjusting the White Balance .......................21

Automatic white balance adjustment .........21

Adjusting the Black Level ............................21

Step 7: Saving the Settings .........................

22

To save user settings ..............................22

To load user settings ...............................23

Main Functions .......................................

 24

Basic Function Matrix .................................

24

GPIO (Digital Input/Output Settings) .........

24

Valid Input/Output Combinations .................24

Camera Output Formats .............................

25

Image Acquisition Controls (Acquisition 

Control)......................................................

29

Changing the Frame Rate ...........................30

Maximum Frame Rate ................................30

Maximum frame rate period formula .........30

During continuous operation ([Frame Start] 

trigger is [Off] or [ExposureMode] is 

[Off]) ................................................32

When [Frame Start] trigger is [On] and 

[TriggerOverLap] is [Off] ......................32

When [Frame Start] trigger is [On] and 

[TriggerOverLap] is [Readout] ..............32

ExposureMode ............................................

33

Actual Exposure Times ...............................33

Trigger Control ...........................................

33

Shortest Repetition Period for Triggers ..........34

Gain Control ...............................................

41

Adjusting the Master Gain and Performing Fine 

Adjustment with R and B (Master Mode) .......41

Adjusting the Gain Individually for RGB 

(Individual Mode) ......................................42

Automatic Gain Level Control ......................42

Lookup Table (LUT) ....................................

43

To use the LUT function ...........................43

LUT values .............................................43

Gamma Function ........................................

44

To use the gamma function ......................44

LineStatus ..................................................

44

BlemishCompensation ................................

44

Automatic detection ................................44

Manual configuration ...............................45

ShadingCorrection ......................................

4

5

FlatShading ...........................................46

ColorShading .........................................46

To use the shading correction function ......47

Binning Function ........................................

4

7

ROI (Regional Scanning Function) ..............

4

7

ROI Settings .............................................47

Sequencer Function ....................................

4

9

ALC (Automatic Level Control) Function ......

51

To use the ALC function ...........................52

Color Space Conversion 

(ColorTransformationControl) .....................

5

2

Note on RGB(UserCustom) ......................52

Edge Enhancer, Color Enhancer ...................

53

CounterAndTimerControl Function ..............

53

Counter occurrence diagram ....................54

Internal camera blocks ............................54

To use the counter function .....................54

VideoProcessBypassMode ...........................

5

5

Functions available in 

VideoProcessBypassMode .....................55

To enable VideoProcessBypassMode ..........55

Settings List ...........................................

 5

6

Feature Properties ......................................

5

6

Miscellaneous .........................................

 6

7

Troubleshooting .........................................

6

7

Specifications .............................................

6

8

Frame Rate Reference ................................

7

1

Spectral Response ......................................

7

1

Dimensions ................................................

7

2

Comparison of the Decibel Display and 

Multiplier Display ........................................

7

3

User’s Record

 .............................................

7

4

Index .....................................................

 7

5

Содержание AP-3200T-PMCL

Страница 1: ...hank you for purchasing this product Be sure to read this manual before use This manual includes important safety precautions and instructions on how to operate the unit Be sure to read this manual to ensure proper operation The contents of this manual are subject to change without notice for the purpose of improvement 2018 JAI ...

Страница 2: ...rt trigger is On and TriggerOverLap is Readout 32 ExposureMode 33 Actual Exposure Times 33 Trigger Control 33 Shortest Repetition Period for Triggers 34 Gain Control 41 Adjusting the Master Gain and Performing Fine Adjustment with R and B Master Mode 41 Adjusting the Gain Individually for RGB Individual Mode 42 Automatic Gain Level Control 42 Lookup Table LUT 43 To use the LUT function 43 LUT valu...

Страница 3: ...t has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interfere...

Страница 4: ...d Hazardous Substances in this camera mark shows that the environment friendly use period of contained Hazardous Substances is 15 years 嶷勣廣吭並 嗤蕎 嗤墾麗嵎賜圷殆兆各式根楚燕 功象嶄鯖繁酎慌才忽佚連恢匍何〆窮徨佚連恢瞳麟半陣崙砿尖一隈〇 云恢瞳ゞ 嗤蕎 嗤 墾麗嵎賜圷殆兆各式根楚燕 泌和 桟隠聞喘豚 窮徨佚連恢瞳嶄根嗤議嗤蕎嗤墾麗嵎賜圷殆壓屎械聞喘議訳周和音氏窟伏翌 亶賜融延 窮徨佚連恢瞳喘薩聞喘乎窮徨佚連恢瞳音氏斤桟廠夛撹冢嶷麟半 賜斤児繁附 夏恢夛撹冢嶷鱒墾議豚 方忖仝15々葎豚 15定 部件名称 有毒有害物质或元素 铅 Pb 汞 Hg 镉 Cd 六价铬 Cr VI 多溴联苯 PPB 多溴二苯醚 PBDE 棱镜 光学滤镜 连接插头 电路板 AP ...

Страница 5: ...our hands or cloth blow with your mouth or use other methods to remove dust Phenomena specific to CMOS image sensors The following phenomena are known to occur on cameras equipped with CMOS image sensors These do not indicate malfunctions Aliasing When shooting straight lines stripes and similar patterns vertical aliasing zigzag distortion may appear on the monitor Blooming When strong light enter...

Страница 6: ...amma correction circuits The ROI and binning functions allow for even faster readout speeds The gain and exposure time can be configured individually for each CMOS sensor A color space conversion function is also supported Features overview Compliance with CameraLink and GenICam standards 1 1 8 inch 3CMOS progressive RGB color camera Lens mount C mount flange back 17 526 mm Effective pixels 2064 H...

Страница 7: ...t X_OUT2 5 18 Out X_Clk CL Clock 6 19 Out X_OUT3 Data out 7 20 In SerTC RxD LVDS Serial Control 8 21 Out SerTFG TxD 9 22 In CC1 Trigger JAI standard trigger 10 23 In CC2 Reserved 11 24 N C 12 25 N C 13 14 Shield Power Return Mount a C mount lens microscope adapter etc here Before mounting a lens be sure to refer to Step 2 Connecting Devices and confirm the precautions for attaching a lens and the ...

Страница 8: ...24 Out Z_Clk CL Clock 12 25 Out Z_OUT3 Data out 13 14 Shield Power Return AP 3200T PMCL 8 3 Power trigger LED Indicates the power and trigger input status LED status and camera status LED Light Status Power trigger LED Lit amber Camera initializing Lit green Operational and no triggers being input Blinking green Operational and triggers being input The blinking interval is not related to the actua...

Страница 9: ...ne 5 6 In Opto IN 1 7 Out Opto OUT 1 Line 2 8 Out Opto OUT 1 9 Out TTL OUT 1 Line 1 10 11 Power IN DC IN DC 12 V to 24 V 10 12 GND Note When DC power is supplied to either Pin 1 Pin 2 or Pin 11 Pin 12 the camera operates Recommended external input circuit diagram reference example TLP2366 1 3 6 5 4 1SS400 180CS BF545C S D G IN USER POWER1 3 3V to 24V CAMERA side User side 3 3V Pin5 Opto In 1 2 Pin...

Страница 10: ...iagram reference example Standard circuit diagram example Pin8 Opto OUT1 Pin7 Opto OUT1 User Side JAI Camera Side Characteristics of the recommended circuits for Opto OUT OUTPUT LINE RESPONSE TIME Output Line Voltage Camera Output Signal RT TDR TDF FT 90 10 Output LEVEL User Vcc 0 8 to 1 1 User power VCC 3 3 V to 24 V Time Delay Rise TDR us 0 5 to 0 7 Tisc Time RT us 1 2 to 3 0 Time Delay Fall TDF...

Страница 11: ...ly When using the camera for the first time install the software for configuring and controlling the camera JAI SDK on the computer When you install JAI SDK JAI Camera Control Tool will also be installed 1 Download the JAI Getting Started Guide and JAI SDK from the JAI website URL http www jai com en support download jai software 2 Refer to the JAI Getting Started Guide and install JAI SDK on the ...

Страница 12: ...gger or 7 AC adapter not supplied 1 Lens C mount lenses with lens mount protrusions of 4 mm or less can be attached 4 mm or less Lens mount protrusion Lens Use a lens designed for three sensor cameras Using a lens for single sensor cameras may hinder full performance of the camera The diagonal of the camera s CMOS image sensor is 8 89 mm the size of standard 1 1 8 inch lenses To prevent vignetting...

Страница 13: ... 8 10 32 bit edition DDR3 4 GB or higher Windows Vista 7 8 10 64 bit edition DDR3 8 GB or higher Graphics card PCI Express 3 0 or higher Network card We recommend using a network card that uses an Intel chip 6 DC IN trigger IN connection cable 7 AC adapter power supply if necessary Connect the AC adapter and the round connector of the connection cable to the DC IN trigger IN connector on the camer...

Страница 14: ...ether power is being supplied to the camera by checking the rear LED Lights green When properly turned on For details on how to read the LEDs see LED status and camera status in the Parts Identification section Step 4 Verifying the Connection between the Camera and PC Verify whether the camera is properly recognized via Control Tool Connecting the Camera to Control Tool 1 Start JAI Control Tool Th...

Страница 15: ...ing settings Confirmation of frame grabber board In order to support GenCP it is necessary to set the COM port on the frame grabber board For details please refer to the instruction manual of each board maker Confirmation of JAI SDK Start JAI Control Tool and click Settings in the upper right AP 3200T PMCL 15 AP 3200T PMCL AP 3200T PMCL AP 3200T PMCL ...

Страница 16: ... The items of JAI_GenCP_Camera_Link and Camera Link Transport Layer are set to the following settings Confirm that it is AP 3200T PMCL 16 ...

Страница 17: ...igure 3 Check that the settings of the selected camera are displayed Check that the settings information of the selected camera appears in the right area If a camera is not detected right click within the window and select Search for Cameras AP 3200T PMCL ...

Страница 18: ...at Configure the size position pixel format of the images ClConfiguration and CameraLinkClockFrequency to be acquired The factory settings are as follows Change the settings as necessary Factory default values Item Default value ImageFormatControl Width 2064 Height 1544 OffsetX horizontal position 0 OffsetY vertical position 0 Pixel Format RGB8 You can specify the image acquisition area For detail...

Страница 19: ...nly be changed when image acquisition on the camera is stopped If an item is grayed out and does not appear even when you select it click Stop Acquisition to stop image acquisition 2 Click and change the setting value Example When changing Width Example When changing PixelFormat Note Direct entry of numerical and text values is possible for some setting items RGB8 RGB10 RGB12 ...

Страница 20: ...ard application Adjusting the Gain Adjust the image quality using the gain and white balance functions To adjust the image quality The display level must be changed from Beginner to Guru Adjust the sensitivity via the analog gain i e master gain For details on gain control see Gain Control in the Main Functions section Manual adjustment 1 Expand AnalogControl and set GainAuto and IndividualGainMod...

Страница 21: ...dualMode set IndividualGainMode to On For details see Gain Control Adjusting the White Balance Adjust the white balance using the automatic adjustment function Automatic white balance adjustment 1 Place a white sheet of paper or similar object under the same lighting conditions as the intended subject and zoom in to capture the white White objects near the subject such as a white cloth or wall can...

Страница 22: ...User Set1 to 3 User memory Temporary memory Current setting values Control Tool Save User Set1 User Set2 User Set3 Note Changes to settings are not saved to the computer Control Tool To save user settings 1 Stop image acquisition 2 Expand UserSetControl and select the save destination UserSet1 to UserSet3 in UserSetSelector Note The factory default setting values are stored in Default and cannot b...

Страница 23: ...ved as user settings To load user settings 1 Stop image acquisition User settings can only be loaded when image capture on the camera is stopped 2 Select the settings to load UserSet1 to UserSet3 in UserSetSelector 3 Select UserSetLoad and click Execute UserSetLoad Command The selected user settings are loaded ...

Страница 24: ...n 1 1 Off 1 2 2 1 2 2 RCT On 1 1 Off 1 2 2 1 2 2 GPIO Digital Input Output Settings The camera is equipped with GPIO general purpose input output functions for generating and using combinations of triggers and other necessary signals within the camera and of signals output from the camera to the system such as those used for lighting equipment control Valid Input Output Combinations The following ...

Страница 25: ... the frame grabber board please refer to the owner s manual of each board TriggerSelector LineSelector PulseGeneratorSelector FrameStart Line1 TTLOut1 Line2 OptOut1 NANDGate0In1 NANDGate0In2 NANDGate1In1 NANDGate1In2 PulseGenerator0 PulseGenerator1 PulseGenerator2 PulseGenerator3 Low High Line5 OptIn1 Line6 OptIn2 UserOutput0 UserOutput1 UserOutput2 UserOutput3 PulseGenerator0 PulseGenerator1 Puls...

Страница 26: ... R6 Port A7 R7 Port B0 G0 Port B1 G1 Port B2 G2 Port B3 G3 Port B4 G4 Port B5 G5 Port B6 G6 Port B7 G7 Port C0 B0 Port C1 B1 Port C2 B2 Port C3 B3 Port C4 B4 Port C5 B5 Port C6 B6 Port C7 B7 Connetor1 Estimated camera link cable length that can be used with this camera 26 The Camera Link cable length is less than 10 m However if CameraLinkClockFrequency is 84 9 MHz the Camera Link cable length is ...

Страница 27: ...3 Port F3 B3 Port C4 B4 Port F4 B4 Port C5 B5 Port F5 B5 Port C6 B6 Port F6 B6 Port C7 B7 Port F7 B7 ClConfiguration Medium PixelFormat RGB10 16 13 14 15 16 13 14 15 16 12 13 14 15 7 8 9 10 11 12 7 8 9 10 11 12 7 8 9 10 11 Connector1 Connector2 1 1 PortA PortB PortC PortD 4 3 5 1 2 PortF PortE 6 6 4 4 5 5 2 2 3 3 6 Port bit 30 bit RGB Port bit 30 bit RGB Port A0 R0 Port D0 Port A1 R1 Port D1 Port ...

Страница 28: ...11 14 PortB 1 4 6 9 12 14 PortC 1 4 7 9 12 15 PortD 2 4 7 10 12 15 PortE 2 5 7 10 13 15 PortF 2 5 8 10 13 16 PortG 3 5 8 11 13 16 PortH 3 6 8 11 14 16 Connector2 Connector1 Port bit 24 bit RGB Port bit 24 bit RGB Port A0 R0 Port D0 R0 Port A1 R1 Port D1 R1 Port A2 R2 Port D2 R2 Port A3 R3 Port D3 R3 Port A4 R4 Port D4 R4 Port A5 R5 Port D5 R5 Port A6 R6 Port D6 R6 Port A7 R7 Port D7 R7 Port B0 G0 ...

Страница 29: ... 24 bit RGB Port bit 24 bit RGB Port A0 R0 Port D0 R0 Port A1 R1 Port D1 R1 Port A2 R2 Port D2 R2 Port A3 R3 Port D3 R3 Port A4 R4 Port D4 R4 Port A5 R5 Port D5 R5 Port A6 R6 Port D6 R6 Port A7 R7 Port D7 R7 Port B0 G0 Port E0 G0 Port B1 G1 Port E1 G1 Port B2 G2 Port E2 G2 Port B3 G3 Port E3 G3 Port B4 G4 Port E4 G4 Port B5 G5 Port E5 G5 Port B6 G6 Port E6 G6 Port B7 G7 Port E7 G7 Port C0 B0 Port ...

Страница 30: ...Maximum frame rate period formula About H_Period For a full image the H_period values are as follows for each ClConfiguration PixelFormat and CameraLink Clock Frequency Base RGB8 55 7 27 85 24 38 Medium RGB8 27 91 13 95 12 22 Medium RGB10 Medium RGB12 Full RGB8 20 96 11 39 11 39 EightyBit RGB8 16 79 11 39 11 39 37 125MHz 74 25 MHz 84 86 MHz 37 125MHz 74 25 MHz 84 86 MHz 37 125MHz 74 25 MHz 84 86 M...

Страница 31: ...846 846 Medium RGB8 846 846 846 Medium RGB10 846 846 846 Medium RGB12 846 846 846 Full RGB8 846 846 846 EightyBit RGB8 846 846 846 37 125MHz 74 25 MHz 84 86 MHz 37 125MHz 74 25 MHz 84 86 MHz 37 125MHz 74 25 MHz 84 86 MHz 37 125MHz 74 25 MHz 84 86 MHz 37 125MHz 74 25 MHz 84 86 MHz 37 125MHz 74 25 MHz 84 86 MHz ClConfiguration PixelFormat CameraLink Clock Frequency Sensor_H_Max Calculate the CL_H_Co...

Страница 32: ..._Period When Frame Start trigger is On and TriggerOverLap is Off Maximum frame rate FR_TrOloff 1 1 FR_Cont NonOverlapExposureTime_TrOloff Calculate the FR_Cont using the following formulas FR_Cont 1 Height 34 H_Period When Frame Start trigger is On and TriggerOverLap is Readout Exposure time possible within frames MaxOverlapTime_TrOlrd 1 FR_Cont 14 H_Period Exposure time outside of frame interval ...

Страница 33: ...osure times that can be configured are as follows ExposureMode Shortest exposure time Timed 14 73 μs 8 bit TriggerWidth 14 73 μs 8 bit Trigger Control The camera allows the following controls to be performed via external trigger signals TriggerSelector Description FrameStart Start exposure in response to the external trigger signal input Select this to perform exposure control using external trigg...

Страница 34: ...icates the shortest trigger periods for when TriggerOverLap is set to Readout When TriggerOverLap is set to Off the exposure time is added to the period CameraLink ClockFrequency RGB8 RGB8 37 125MHz 74 25 MHz 84 86 MHz Base Medium RGB10 Medium RGB12 RGB8 Medium Ful RGB8 EightyBit Minimum trigger pulse width Camera Link TTL In 3 μs 50 ns 44 0ms 22 0ms 38 5ms 19 3ms 44 0ms 38 5ms 44 0ms 18 0ms 38 5m...

Страница 35: ...84 86 81 908 34 1544 1578 19 265 51 91 37 125 17 952 34 1544 1578 87 9 11 38 74 25 35 904 34 1544 1578 43 95 22 75 84 86 41 033 34 1544 1578 38 456 26 37 125 17 952 34 1544 1578 87 9 11 38 74 25 35 904 34 1544 1578 43 95 22 75 84 86 41 033 34 1544 1578 38 456 26 37 125 47 719 34 1544 1578 33 069 30 24 74 25 87 766 34 1544 1578 17 98 55 62 84 86 87 765 34 1544 1578 17 98 55 62 37 125 59 495 34 1544...

Страница 36: ... 1036 13 95 71 67 84 86 4 1032 1036 12 21 81 908 37 125 4 2064 2068 55 7 17 952 74 25 4 2064 2068 27 85 35 904 84 86 4 2064 2068 24 37 41 033 37 125 4 2064 2068 55 7 17 952 74 25 4 2064 2068 27 85 35 904 84 86 4 2064 2068 24 37 41 033 37 125 4 774 778 20 96 47 719 74 25 72 774 846 11 39 87 766 84 86 193 774 967 11 39 87 766 37 125 4 620 624 16 81 59 495 74 25 226 620 846 11 39 87 766 84 86 347 620...

Страница 37: ... 43 381 94 12 22 38 338 77 Medium RGB10 Medium RGB12 Full RGB8 20 96 64 556 157 11 39 35 318 70 11 39 35 318 70 EightyBit RGB8 16 79 51 452 119 11 39 35 318 70 11 39 35 318 70 CameraLink Clock Frequency 37 125MHz 74 25 MHz 84 86 MHz 37 125MHz 74 25 MHz 84 86 MHz 37 125MHz 74 25 MHz 84 86 MHz 37 125MHz 74 25 MHz 84 86 MHz 37 125MHz 74 25 MHz 84 86 MHz 37 125MHz 74 25 MHz 84 86 MHz Period from Trigg...

Страница 38: ...MHz 37 125MHz 74 25 MHz 84 86 MHz 37 125MHz 74 25 MHz 84 86 MHz 37 125MHz 74 25 MHz 84 86 MHz 37 125MHz 74 25 MHz 84 86 MHz 37 125MHz 74 25 MHz 84 86 MHz Period from Trigger start edge to Exposure start A usec Period from Exposure end to FVAL start B usec Period from Exposure end to next trigger start C usec 55 70 27 85 24 38 27 91 13 95 12 22 20 96 11 39 11 39 16 79 11 39 11 39 55 70 27 85 24 38 ...

Страница 39: ...rt C usec Period from Trigger end edge to Exposure end D usec Base RGB8 Medium RGB8 Medium RGB10 Medium RGB12 Full RGB8 EightyBit RGB8 CameraLink Clock Frequency 37 125MHz 74 25 MHz 84 86 MHz 37 125MHz 74 25 MHz 84 86 MHz 37 125MHz 74 25 MHz 84 86 MHz 37 125MHz 74 25 MHz 84 86 MHz 37 125MHz 74 25 MHz 84 86 MHz 37 125MHz 74 25 MHz 84 86 MHz 55 70 27 85 24 38 27 91 13 95 12 22 20 96 11 39 11 39 16 7...

Страница 40: ...RGB8 948 475 415 Medium RGB8 476 238 209 Medium RGB10 Medium RGB12 Full RGB8 357 195 195 EightyBit RGB8 286 195 195 CameraLink Clock Frequency 37 125MHz 74 25 MHz 84 86 MHz 37 125MHz 74 25 MHz 84 86 MHz 37 125MHz 74 25 MHz 84 86 MHz 37 125MHz 74 25 MHz 84 86 MHz 37 125MHz 74 25 MHz 84 86 MHz 37 125MHz 74 25 MHz 84 86 MHz 55 70 27 85 24 38 27 91 13 95 12 22 20 96 11 39 11 39 16 79 11 39 11 39 55 70...

Страница 41: ...o Off Adjust the AnalogAll master gain setting first and then adjust the AnalogRed DigitalRed AnalogBlue and DigitalBlue setting values to perform fine adjustment When IndividualGainMode is set to Off 0 dB 18 dB 6 5 dB 12 dB 0 915 dB 0 828 dB 6 5 dB 12 dB 0 828 dB 6 5 dB 12 dB 0 915 dB 0 828 dB 6 5 dB 12 dB 0 915 dB 0 828 dB 6 215 dB 30 828 dB AnalogAll AnalogRed DigitalRed AnalogBlue DigitalBlue ...

Страница 42: ...t to Continuous you can configure the conditions for automatic adjustment in detail Item Description ALCReference Specify the target level for automatic gain control This setting is also used for automatic exposure control ALCAreaEnableAll Select whether to specify all areas as auto gain metering areas or whether to specify the areas individually False Specify areas as auto gain metering areas 16 ...

Страница 43: ...n Configure the settings as follows Item Setting value selectable range Description LUTMode LUT Use LUT LUTSelector Red Green Blue Select the LUT channel to control LUTIndex 0 to 256 Select the LUT index to configure Indexes represent the possible pixel values captured on the sensor from the lowest value Index 0 to the highest Index 256 For example Index 0 represents a full black pixel and Index 2...

Страница 44: ...0 55 0 6 0 65 0 75 0 8 0 9 1 0 Select the gamma correction value JAI LUTMode Gamma Use gamma Note You can use the LUT function to configure a curve with more detailed points For details see Lookup Table LUT LineStatus The line status function allows you to verify the status of external input output signals You can verify the status of the following signals Line1 TTLOut1 Line2 OptOut1 Line5 OptIn1 ...

Страница 45: ...ary as 1 If 0 is specified the first line or first pixel will be interpolated Note BlemishCompensationDataClear specify sensor BlemishCompensationIndex you can return a specific pixel correction setting to the default value storage not required 3 Execute BlemishStore Blemish compensation data will be stored 4 Set BlemishEnable to True and execute interpolation If it is set to False Blemish compens...

Страница 46: ...ctive pixels The following shading correction modes are available on the camera FlatShading Correction is performed using the area of the screen with the highest brightness level as the reference and adjusting the brightness levels of the other areas to match this level ColorShading R channel and B channel properties are adjusted to using the G channel shading properties as a reference 17 1 2 3 4 ...

Страница 47: ...ing correction is executed the shading correction value is automatically saved to the user area selected in ShadingMode Binning Function The binning function allows you to combine the signal values of clusters of adjacent pixels to create improved virtual pixels Using the function results in images with lower pixel resolution and higher sensitivity This camera performs vertical binning and horizon...

Страница 48: ...6 pxels step BinningVertical Off 0 to 1542 2 lines step BinningHorizontal On 0 to 1024 8 pxels step BinningVertical On 0 to 770 2 lines step Example 1 Without binning BinningHorizontal 1 BinningVertical 1 OffsetX OffsetY Height Width 1544 Height Max 2064 Width Max Scanning range Example 2 With binning BinningHorizontal 2 BinningVertical 2 OffsetX OffsetY Height Width 772 Height Max 1032 Width Max Scan...

Страница 49: ... Set the next index to be displayed for the selected SequencerIndex SequencerWidth SequencerBinningHorizontal 1 96 to 2064 SequencerBinningHorizontal 2 48 to 1032 2064 Set the width of the selected SequencerIndex SequencerHeight SequencerBinningVertical 1 2 to 1544 SequencerBinningVertical 2 2 to 772 1544 Set the Height of the selected SequencerIndex SequencerOffsetX SequencerBinningHorizontal 1 0...

Страница 50: ...e sequence When gamma is selected the gamma setting defined in AnalogControl is applied to all exposures in the sequence When LUT is selected the LUT characteristics defined in AnalogControl are applied to indexes for which SequencerLUT enable is set to ON SequencerReset During TriggerSequencer mode operation this switches the index number to be executed to Sample TriggerSequencer mode operation U...

Страница 51: ...s unless the CommandSequencerIndex value is changed SequencerFrameNumber and SequencerSetNext cannot be used in CommandSequencer mode Index1 ROI1 Exposure 1 Gain1 M Red Blue Black Level1 Binning1 H V LUT Enable1 Frame Count1 Next Index1 Index2 ROI2 Exposure 2 Gain2 M Red Blue Black Level2 Binning2 H V LUT Enable2 Frame Count2 Next Index2 Index128 ROI128 Exposure 128 Gain128 M Red Blue Black Level1...

Страница 52: ...This camera allows you to convert the standard color space RGB that is used to produce colors into other color spaces including XYZ and HSI Five color spaces are available RGB sRGB RGB AdobeRGB RGB UserCustom XYZ and HSI Specify the desied color space by configuring ColorTransofrmationMode and ColorTransformationRGBMode as follows ColorTransformation ColorTransformationMode ColorTransformationRGBM...

Страница 53: ...Enable Color is set to True Set a value from 0 to 1 0 1 steps for ColorEnhancerValue ColorEnhancerSelector to set the enhancement to one of ten levels 0 no enhancement 1 approx x2 the color level of the original data Six colors can be specified in ColorEnhancerSelector Red Cyan Green Magenta Blue and Yellow CounterAndTimerControl Function This camera supports only the counter function The counter ...

Страница 54: ...ion to the HOST Event detection Event detection Counter0 FrameStartTrigger Counter1 ExposureStart Counter2 SensorReadOut To use the counter function Configure the settings as follows Four counters are available Specify a counter Counter0 to Counter3 and configure the settings Item Setting value selectable range Description Counter 0 to 2 Counter 0 to 2 Select the counter CounterEventSource Counter...

Страница 55: ... DigitalBlue BlackLevel LUT Shading Binning H V Enhancement ColorMatrix All video processes are enabled Camera output Base RGB8 Medium RGB8 RGB10 Full RGB8 EightyBit RGB8 Medium RGB12 Functions available in VideoProcessBypassMode The following functions can be used in video process bypass mode Gain AnalogAll Gain AnalogRed Gain AnalogGreen Gain AnalogBlue AutoGainControl AutoShutterControl AutoWhi...

Страница 56: ...00 Baud38400 Baud57600 Baud115200 Baud230400 Baud460800 Baud921600 Baud9600 Displays the baud rate of the serial port DeviceReset Reset the device b ImageFormatControl Configure image format settings SensorWidth 2064 2064 Display the maximum image width SensorHeight 1544 1544 Display the maximum image height SensorDigitizationBits 12 Bits 12 Bits Display the number of bits at which the sensor is o...

Страница 57: ...isitionFrameRate Hz 0 125 to 55 6 Full Set the frame rate as a frequency unit Hz The maximum value varies depending on the PixelFormat and ROI settings TriggerSelector FrameStart FrameStart Select the trigger operation TriggerMode Off On Off Select the trigger mode TriggerSoftware Execute a software trigger TriggerSource Low High Software PulseGenerator0 3 User Output 0 3 Line 5 OptIn1 Line 6 OptI...

Страница 58: ... gain setting selected in GainSelector GainAuto Off Continuous Once Off Enable disable gain auto adjustment Once automatically changes to Off when the signal level converges once BalanceWhiteAuto Off Continuous Once ExposureContinuous ExposureOnce Preset3200K Preset5000K Preset6500K Preset7500K Off Enable disable auto white balance WB adjustment via gain adjustment Continuous Once WB adjustment vi...

Страница 59: ...e polarity inversion for the selected input signal or output signal LineStatus True False False Display the status of the input signal or output signal True High False Low LineSource Low High FrameTriggerWait FrameActive ExposureActive FVAL LVAL PulseGenerator0 3 UserOutput0 3 Line5OptIn1 Line6OptIn2 Line7 CC1 NAND0Out NAND1Out Low Select the line source signal for the item selected in LineSelecto...

Страница 60: ...ve Display the counter status CounterIdle Idle CounterActive Counting CounterOverflow Count value exceeded the maximum value i UserSetControl Configure user settings UserSetSelector Default UserSet1 to 3 Default Select the user settings UserSetLoad Load user settings UserSetSave Save the current setting values as user settings j SequencerControl Configure sequencer settings SequencerMode On Off Of...

Страница 61: ...e selected SequencerIndex SequencerGain AnalogAll 1 0 to 8 0 1 0 Set the GainAnalogAll value SequencerGain AnalogRed 0 47 to 4 0 1 0 to 64 0 1 0 SequencerGain AnalogGreen 1 0 fixed 1 0 to 64 0 1 0 SequencerGain AnalogBlue 0 47 to 4 0 1 0 to 64 0 1 0 SequencerExposure TimeCommon µs Set the exposure time for the selected SequencerIndex SequencerExposure TimeRed µs SequencerExposure TimeGreen µs Sequ...

Страница 62: ...t Medium CameraLinkClockFrequendy 37 1MHz 74 3MHz 84 9MHzk 74 3MHz n JAICustomControl PulseGenerators Configure pulse generator settings ClockPreScaler 1 to 4096 165 Set the division value for the prescaler 12 bit using PixelClock as the base clock PulseGeneratorClock MHz 0 018127 to 74 25 0 45 Set the clock used for the pulse generator This value is calculated using the ClockPreScaler value as a ...

Страница 63: ...reaches this value the output will be 0 PulseGeneratorEnd Point ms 1 PulseGeneratorClock MHz to 1048575 PulseGeneratorClock MHz 33 3333 Set the start point of the Low interval in milliseconds When the counter reaches this value the output will be 0 The setting range varies depending on the ClockPreScaler value PulseGeneratorPulse width ms 33 3333 Display the High interval width of the pulse in mil...

Страница 64: ...ea states configured in ALCAreaSelector Off Operate ALC according to the individual enabled disabled photometry area states configured in ALCAreaSelector AutoShutterControl ExposureMin 100 to 13426 100 Set the minimum value for the ExposureAuto ASC control range AutoShutterControl ExposueMax 101 to 13427 Set the maximum value for the ExposureAuto ASC control range AutoGainControlGainRaw Min 100 to...

Страница 65: ...False True Enable disable blemish correction BlemishDetect Execute blemish detection BlemishStore Save the location information of detected blemishes BlemishSelector Red Green Blue Specify the sensor for which to configure Blemish BlemishDetect Threshold 0 to 100 10 Set the blemish detection threshold BlemishCompensation Index 1 to 200 Select the index for the target blemish coordinates BlemishDat...

Страница 66: ...s VideoProcessBypassMode On Off Off Enable disable VideoProcessBypass mode EnhancerSelector Edge Color Specify the operation mode for Enhancer EnhancerEnable True False Enable disable EdgeEnhancer and ColorEnhancer ColorEnhancerSelector Red Cyan Green Magenta Blue Yellow Index for advanced ColorEnhancer settings ColorEnhancerValue 0 to 1 0 Specify the ColorEnhancer emphasis levels for each color c...

Страница 67: ...on to correct the display As the light emitting properties of the monitor are not linear the entire image may be darker or the gradation in the dark areas may be less noticeable when camera outputs are displayed without processing Using the gamma function performs correction to produce a display that is close to linear For details see Gamma Function Settings and operations Problem Cause and soluti...

Страница 68: ...lector Exposure FrameStart ExposureMode Off Timed TriggerWidth PWC Trigger overlap Off Readout Trigger input signals Low High Software PulseGenerator0 3 UserOutput0 3 Line5 OptIn1 Line6 OptIn2 NAND0Out NAND1Out Opto filter Off default 100 µs 500 µs 1ms 5ms 10ms Exposure Mode Timed 14 73 µs 8 bit 14 73 µs 10 bit min to 8 s max Trigger Width 14 73 µs 8 bit 14 73 µs 10 bit min to 8 s max Performance ...

Страница 69: ... at factory Correction Interpolation using adjacent pixels continuous blemishes not corrected Correctable pixels 200 pixels per sensor ALC Can be adjusted automatically together with AGC and auto exposure control Gamma 0 45 0 5 0 55 0 6 0 65 0 75 0 8 0 9 1 0 9 steps available LUT OFF γ 1 0 ON 257 points can be set Vibration resistance 3 G 20 Hz to 200 Hz X Y Z direction Impact resistance 50 G Powe...

Страница 70: ...red to achieve these specifications Caution About the verified performance temperature Make sure the following temperature conditions are met when operating the unit 1 The camera s internal temperature sensor detects temperatures of 72 C or less during operation 2 The top surface of the camera s casing is 57 C or less If the above temperature conditions are exceeded take measures to dissipate heat...

Страница 71: ...OI 3 45 3 45 1 2 8 5 66 mm 0 5 MP 800 600 ROI 3 45 3 45 1 4 6 3 45 mm 0 5 MP 800 600 ROI 2 2 Binning 6 9 6 9 1 2 3 6 9 mm 0 3 MP 640 480 ROI 3 45 3 45 1 5 75 2 76 mm 0 3 MP 640 480 ROI 2 2 Binning 6 9 6 9 1 2 9 5 52 mm Spectral Response 0 0 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 0 9 1 400 500 600 700 800 Relative Sensitivity wavelenth nm AP 3200T PMCL Sensitivity AP 3200T_Bch AP 3200T_Gch AP 3200T_Rch 78 8...

Страница 72: ... 72 AP 3200T PMCL Dimensions Dimensional tolerance 0 3 mm Unit mm DC IN TRIG 3 68 26 26 4 M3 Depth3 POWER TRIG 44 44 C Mount 74 6 3 0 5 3 68 4 M3 Depth3 DIGITAL I O 1 DIGITAL I O 2 ...

Страница 73: ...818 10 3 162 11 3 548 12 3 981 Near maximum value of Gain AnalogRed AnalogBlue 4 13 4 467 14 5 012 15 5 623 16 6 31 17 7 079 18 7 943 Near maximum value of Gain AnalogAll 5 19 8 913 20 10 21 11 22 22 12 589 23 14 125 24 15 849 25 17 783 26 19 953 27 22 387 28 25 119 29 28 184 30 31 623 31 35 481 32 39 811 33 44 668 34 50 119 35 56 234 36 63 096 Near maximum value of Gain AnalogIndividualRed Green ...

Страница 74: ...and Windows are trademarks or registered trademarks of Microsoft Corporation in the United States and other countries Intel and Intel Core are trademarks of Intel Corporation in the United States and other countries Other system and product names described in this document are trademarks or registered trademarks of their respective owners The and symbols are not used in this document ...

Страница 75: ... Input Output Settings 24 Dimensions 72 E Edge Enhancer 53 ExposureMode 33 FeatureProperties 56 Frame Rate 30 Frame Rate Reference 71 G Gamma Function 44 GPIO 24 I Installing the Software 11 P 7 L LED 8 Lens 12 Lens mount 12 LineStatus 44 Lookup Table 43 LUT 43 M Maximum Frame Rate 30 O Optional accessories not supplied 70 Output format 25 Parts Identification POWER TRIG LED 8 R Regional Scanning ...

Страница 76: ...Revision history Revision Date Changes 1 0 Apr 2018 First version 1 1 Mar 2019 Add KC Fix Contents and Index 1 2 Jun 2019 Vertical timing chart LAVL ...

Отзывы: