10
—
AP-3200T-
PMCL
⑤
Camera locking screw holes (M3, 3 mm depth)
Use these holes when attaching an MP-44 tripod adapter plate (optional) or mounting the
camera directly to a wall or other structural system.
Recommended external output circuit diagram (reference example)
Standard circuit diagram example
Pin8
(Opto OUT1 +)
Pin7
(Opto OUT1 -)
User Side
JAI Camera Side
Characteristics of the recommended circuits for Opto OUT
OUTPUT LINE RESPONSE TIME
Output
Line
Voltage
Camera
Output
Signal
RT
TDR
TDF
FT
90%
10%
Output LEVEL = User Vcc- (0.8 to 1.1)
User power (VCC)
3.3 V to 24 V
Time Delay Rise TDR (us)
0.5 to 0.7
Tisc Time RT (us)
1.2 to 3.0
Time Delay Fall TDF (us)
1.5 to 3.0
Fall Time FT (us)
4 to 7