7
QS WM Instrument Shelf:
HARDWARE KIT QS-HWR045
Step 1:
Place the instrument top upside down on smooth flat surface being sure to protect it from damage by foreign
objects. IAC recommends the use of packing type blankets or clean cardboard. Place the riser boxes onto the
instrument shelf aligning the slots in the riser boxes with the threaded inserts in the instrument shelf as
shown. The side of the riser box that has holes in it, face the rear of the instrument shelf. Thread 1/4-20 x .75
hex head bolts and 1/4” flat washers into the threaded inserts in the instrument shelf. DO NOT TIGHTEN
THIS HARDWARE.
Step 2:
Connect the support beam
to the riser boxes using the 1/4-20 x .75" hex head bolts 1/4" flat washers and 1/4-
20 keps nuts. Align support beam ends with holes in riser boxes and push bolts through the support beam
ends plates and holes in the riser boxes. Attach keps nuts to bolts on the inside of riser boxes and tighten.
Align the riser boxes to even the overhangs and then tighten riser box attachment hardware. Install all plastic
cap plugs that apply. If you have Riser
Electrical Panels do not install the 1.5” cap plug.
Note:
If you are assembling a 96” instrument shelf you will have a second beam that is mounting in rear of the
shelf the same as in the front.
Note:
If you are installing a WM Undershelf Light please see page 9 at this time.