41
•
Shutter First:
Enable the Shutter First mode that is Fix shutter and you can select the AGC
(Auto
gain control) value. High AGC value will get the bright image, but the video
noise will be increasing.
•
Gain First:
Enable the Gain First mode and you can select the Shutter value from 1/5s ~
1/100,000s. And AGC will become to auto mode.
Select the shutter value for the
application.
Aperture:
•
IRIS:
Select the Manual/DC-IRIS/P-IRIS
mode, it should be matched the IRIS of Lens type.
•
Lens:
Select the Manual/Semiautomatic
mode, it should be matched the Lens type
which can
support the auto focus.
Gamma:
•
Gamma:
Select the value to suit for the environment application.
•
Power Frequency:
There are 2 kind frequencies on the power system and it will cause the line
scrolling on the video if the frequency does not match. Select the correct power
frequency to match the used power system.
Light Board Control:
•
Model:
There are Auto/Manual/Off modes to control the IR LED.
Auto:
Select the Auto mode, the IE LED will adjust the optimum status when viewing the
object automatically.
Manual:
Select the Manual
mode;
you can adjust the bright of LED by manually.
Off:
Select the Off
mode;
the IR LED will be turned off.
Save:
Click the Save icon to setup the parameters.