ON /OFF button  

 

Polarity of power supply 

 

Stop treatment  

 

Start/Pause button  

 

Protected against the effects of immersion: for ultrasound 
handle 

 

WEE Regulations 

 

Applied part type BF 

 

Product in compliance with Directive 93/42/EEC (MDD) 

 

 

Device can supply a current > 10mA r.m.s. or 10V r.m.s. for a 
period of 5 seconds  

 

Fabricant name and address 

 

Manufacturing date (month/year) 

 

Attention. Consult operating instructions  

 
 

Ultrasound handle lot 

 
 

Serial number of ultrasound handle  

E

E

M

M

 

 

C

C

O

O

M

M

P

P

A

A

T

T

I

I

B

B

I

I

L

L

I

I

T

T

Y

Y

 

 

 

 

E

E

M

M

C

C

 

 

T

T

A

A

B

B

L

L

E

E

S

S

 

 

 

 

Use the I-TECH UT1  device at least 3 metres away from televisions, monitors, mobile 
phones, WIFI routers or any other electronic device as they may affect its functioning. 

The  device  must  be  installed  and  commissioned  in  compliance  with  the  information 
on  electromagnetic  compatibility  supplied  in  this  manual.  Also  see  the  EMC  Charts 
paragraph. 

Using accessories, transducers and cables other than those specified, except for those 
transducers  and  cables  sold  by  the  manufacturer  as  spare  parts  for  internal 
components, may result in increased emissions or decreased immunity of the device. 

The device should not be placed next to or on  top of  other devices. Should it prove 
necessary to place it next to or on top of other devices, supervision is essential at all 
times to control its normal functioning.  

 

Guidance and manufacturer's declaration – electromagnetic emissions  

FOR ALL EM DEVICES 

The I-TECH UT1 device

 

is intended for use in the electromagnetic environment specified below. The 

customer or the user of the I-TECH UT1 should assures that it is used in such an environment. 

Emissions test 

Compliance 

Electromagnetic environment - guidance 

RF emissions 
CISPR 11 

Group 1 

The  I-TECH  UT1  device  uses  RF  energy  only  for  its 
internal  function.  Therefore,  its  RF  emissions  are 
very  low  and  are  not  likely  to  cause  any 
interference in nearby electronic equipment. 

RF emissions 
CISPR11 

Class B 

The  I-TECH  UT1  device  is  suitable  for  use  in  all 
establishments  other  than  domestic  and  those 
directly connected to the public l o w - v o l t a g e 
p o w e r s u p p l y network that supplies buildings 
used for domestic purposes. 

Harmonic emissions 
lEC 61000-3-2 

N.A. 

Voltage 

fluctuations 

flicker emissions 
lEC 61000-3-3 

N.A.  

Guidance and manufacturer's declaration-electromagnetic 

Immunity 

 

The I-TECH UT1 device is intended for use in the electromagnetic environment specified below. The 
customer or the user of the I-TECH UT1 should assure that it is used in such an environment. 

LOT 

SN 

Содержание UT1

Страница 1: ...MNPG116 Rev 0 01 08 2013...

Страница 2: ...OF USE and EQUIPMENT 5 DEVICE DESCRIPTION 6 INSTALLATION 9 PRELIMINARY OPERATIONS 9 ULTRASOUND TREATMENT 10 CLEANING MAINTENANCE AND STORAGE 16 OPERATION TROUBLES 16 ENVIRONMENT PROTECTION 17 TECHNIC...

Страница 3: ...a later date on the basis of acquired experience The manufacturer reserves the right to update the production and the manuals with no obligation to update previous versions The manufacturer declines...

Страница 4: ...r radiations should not be treated with ultrasounds Using ultrasounds on the stellate ganglion on the spinal column after a laminectomy on the area surrounding the main nerves or the cranium should be...

Страница 5: ...cated for several chronic and sub chronic treatments as Muscle pains and contractures Contractures Capsulitis Bursitis Myositis Soft tissues diseases Tendinitis Tendinosis Use hospital and domestic us...

Страница 6: ...IO ON N 1 Program selection button 2 Frequency selection button 1 3MHz 3 Duty cycle selection button 4 Timer selection button 5 LCD display 6 STOP button 7 Intensity selection knob and PAUSE 8 Handle...

Страница 7: ...am indicator 2 Frequency indicator 1 3MHz 3 Duty cycle indicator 4 Timer indicator 5 Output intensity power indicator 6 Ultrasound head detector 7 PAUSE therapy indicator 1 Ultrasound head 2 LED for u...

Страница 8: ...und handle WEE Regulations Applied part type BF Product in compliance with Directive 93 42 EEC MDD Ultrasound intensity Ultrasound applicator state contact head skin Indicator of connection socket of...

Страница 9: ...is found an error code will appear on the display please read the paragraph Operation troubles to get more details Before starting treatment please pay attention to the following suggestions Put the...

Страница 10: ...E conductive gel CE 6 Regulate the intensity of the treatment using the knob 7 Press any of the PROGRAM FREQUEN DUTY CYCLE or TIME buttons during the treatment to visualise W Watts or W cm Watt sq cm...

Страница 11: ...re the only parts protected against water damage with a IPX7 grade ATTENTION Never apply the gel to the ultrasound head The treatment head will register this as contact and may emit ultrasound energy...

Страница 12: ...cted area 1MHz 50 15 min 5 cmq 1 5W cm 2W cm 10 15 Bursitis U 01 10 Affected area 1MHz 30 15 min 5 cmq 2W cm 10 15 Brachialgia U 01 10 Trapezium and arm 1MHz 30 15 min 5 cmq 2W cm 10 15 Capsulitis U 0...

Страница 13: ...le pain U 01 10 Affected area 1MHz 50 15 min 5 cmq 1 0W cm 1 5W cm 10 15 Rheumatic pain U 01 10 Affected area 1MHz 50 15 min 5 cmq 1 0W cm 1 5W cm 10 15 Dorsalgy U 01 10 Dorsal area 1MHz 50 15 min 5 c...

Страница 14: ...balgy U 01 10 Internal thigh upper zone 1MHz 50 15 min 5 cmq 1 0W cm 1 5W cm 10 15 Radiculitis U 01 10 Affected area 1MHz 50 15 min 5 cmq 1 0W cm 1 5W cm 10 15 Muscle recovery U 01 10 Affected area 1M...

Страница 15: ...ion U 01 10 Affected area 1MHz 60 15 min 5 cmq 2W cm Free Indications regarding intensity and number of sessions can vary depending on the opinion of your personal doctor or therapist In particular in...

Страница 16: ...more information about the original accessories and spare parts contact I A C E R Srl authorized centers After cleaning the external box dry all of the parts carefully before turning on the device Do...

Страница 17: ...nsions 143mmx73mmx40mm Device Dimensions 250mmx185mmx82mm Environmental conditions for use Temperature from 10 C to 40 C Relative humidity 30 85 Atmospheric pressure 800 1060hPa Environmental conditio...

Страница 18: ...should not be placed next to or on top of other devices Should it prove necessary to place it next to or on top of other devices supervision is essential at all times to control its normal functionin...

Страница 19: ...Electromagnetic environment guidance Conducted RF lEC 61000 4 6 3V effective from 150kHz to 80MHz 3V V1 Portable and mobile RF communications equipment should be used no closer to any part of the I TE...

Страница 20: ...y starting from the purchase date covering electric and electronic parts for household use In case of purchase from professional operators purchase with an invoice the warranty is 12 months All of the...

Страница 21: ...I A C E R Srl 21 I TECH UT1 All rights riserve I TECH UT1 and logo are owned by IACER and are registered...

Страница 22: ...I A C E R Srl 22...

Страница 23: ...I A C E R Srl 23...

Страница 24: ...iva e magazzino 30030 MARTELLAGO VE Via S Pertini 24 A Tel 0039 041 5401356 Fax 0039 041 5402684 Cod Fisc P IVA IT 00185480274 R E A VE N 120250 M VE001767 e mail iacer iacer it Internet www itechmedi...

Отзывы: