background image

 

MNPG127-02 

Pag. 5 

 

- use of non-original accessories.  

The warranty is supplied ex works. 

Should  you  need  to  return  the  goods  then  please  note  the  packing  instructions  as 
follows. Enclose a copy of the purchasing receipt.  

Before sending the machine back for suspected malfunction, we recommend that first 
you  carefully  consult  sections  regarding  MAINTENANCE  and  TROUBLESHOOTING  of 
the manual, as a large part of the problems and faults are usually due to inadequate 
maintenance or small technical problems which can often be easily solved by the user 
himself.  

When re-packing the equipment for return to the manufacturer, proceed as follows: 

1. unplug the machine and any connections, devices, applicators etc; 

2. carefully clean and disinfect all parts of the machine and accessories which have  

been in contact with patients; 

Any  equipment  which  the  technical  department  does  not  consider  hygienic  (Italian 
law T.U.S. 81/2008 on safety in the workplace) will not be accepted; 

3. disassemble accessories and any mechanical supports; 

4. use original box and packing materials; 

5  Enclose  detailed  information  regarding  the  nature  of  the  problem  in  order  to 
facilitate the technical department’s intervention and save time on repair. 

NOTES 

PRELIMINARY NOTES 

 

The installation of the device does not require any special care, is therefore 
simple and immediate.

 

 

MAINTENANCE 

 

 For an optimal use of the device and to guarantee its maximum performance, it 
is  recommended  to  perform  maintenance  at  the  correct  time  and  suggested 
ways. 

 
 
 
 
 

CAUTIONS  

PRELIMINARY NOTES  

-

 

The customer is liable for all damage caused by inadequate packaging of the 
material. Keep the original packaging of the unit: it will be needed if the unit 
is returned to the company.   

-

 

Do not use the equipment in places where it might get wet.  

-

 

Before  operating  the  machine  carefully  check  the  correctness  of  the 
connections  according to the instructions.  

-

 

Do not use accessories other than the ones provided: they might damage the 
unit, causing the warranty to become void. In case you have any problems or 
difficulties with installation, contact I.A.C.E.R. srl technical support.  

-

 

If using the same extension for the unit and other units, make sure that the 
total  current  being  absorbed  by  the  connected  units,  does  not  exceed  the 
max  current  allowed  for  that  type  of  cable  and  that,  however,  it  does  not 
exceed 15 A. 

-

 

The protocols of therapeutic suggestion preloaded on the machine cannot be 
deleted. 

-

 

It  is  not  possible  to  define  a  number  of  sessions  suggested  to  evaluate  the 
effectiveness of the treatment, since they are related to the power delivered 
to the patient undergoing treatment. It is task of the physician to decide the 
number  of  therapy  sessions  which  subject  the  patient  according  to  the 
specific  requirements  of  the  case,  in  order  to  ensure  to  the  patient  himself 
the  execution  of  an  effective  treatment  in  time  and  place  in  conditions  of 
absolute safety.  

-

 

Always  control  sometimes  the  integrity  of  the  cable  and  of  the 
probe/applicator connector: they must not be damaged or worn.  

USE 

-

 

The laser radiation that outgoings from the device is dangerous: always use 
the appropriate glasses, always avoid the exposition of the eyes to the direct 
or reflected laser beam

 

 

-

 

Before beginning any treatment both operator and patient must wear the 
PROTECTIVE GLASSES 

 

-

 

Before switching the device on, be sure that the INTERLOCK key, that allows 
to start up the machine, is connected. 

-

 

Because of security reasons, the only specific software must be loaded into 
each  machine.  In  case  of  exchange  of  software,  the  machine  may 
immediately stop all its functions, requiring the intervention of I.A.C.E.R. srl 
technical assistance. 

Содержание LA500

Страница 1: ...I A C E R Srl MNPG127 02 06 06 17 LASER THERAPY...

Страница 2: ......

Страница 3: ...E 8 INDICATIONS 8 CONTRA INDICATIONS 8 DEVICE DESCRIPTION 9 PATIENTS PREPARATION 9 HOW TO USE IT 9 Therapeutic indications 11 MAINTENANCE 13 HANDLES CLEANING 13 WORKING PROBLEM 13 ELECTROMAGNETIC INTE...

Страница 4: ...important information and useful tips for operating the equipment CAUTIONS The CAUTION message appears before operations which if not correctly performed may cause damage to the machine and or its acc...

Страница 5: ...t use the equipment in places where it might get wet Before operating the machine carefully check the correctness of the connections according to the instructions Do not use accessories other than the...

Страница 6: ...ecution of different procedures from those specified in this user manual can cause the exposition to dangerous radiation The operator has the responsibility to verify that the issuing head remains wel...

Страница 7: ...er production of ATP The applications of the I TECH LA500 laser produce a number of effects on the treated tissues 1 increase in hematic flow vasodilatation of capillaries and arteries 2 biostimulatio...

Страница 8: ...ensitive to laser radiation and can be permanently damaged from direct or reflected laser beams The special safety glasses must be worn by both patient by the operator pregnancy the laser is contraind...

Страница 9: ...of the patient for the therapy carry out the following operations 1 wash the skin using soap and mild soap or alcohol where the head of the laser will be positioned 2 dry well the skin HOW TO USE IT...

Страница 10: ...ent time last 3 minutes Select the operation mode CONTINUOS or CYCLE using the buttons on the right side of the front panel picture below With CYCLE mode it is possible to select the ON time from 1 to...

Страница 11: ...ition upper picture Take away the key from the machine to avoid the use by unauthorized personnel Please do not switch off the device unplugging the cable from the power socket to avoid any type of da...

Страница 12: ...ITIS 0 3 66 sec 264 sec BAKER S CYST 0 3 66 sec 264 sec DE QUERVAIN SYNDROME 0 2 100 sec 400 sec OEDEMA 0 3 66 sec 264 sec HEMATOMA 0 3 66 sec 264 sec EPICONDYLITIS 0 4 50 sec 200 sec HERNIATED DISC 0...

Страница 13: ...ent HANDLES CLEANING The laser handle is very weak and it needs a daily cleaning The following advices are absolutely important to not damage the lens and the laser probe It is suggested to 1 Remove t...

Страница 14: ...that the socket works properly The power cable is not inserted correctly into the connector of the device Insert correctly the plug and the cable in the connector of the device The power cable is wor...

Страница 15: ...B Output channels 1 Class of isolation parts applied according to the rule EN 60601 1 I BF Protection level against the liquids penetrations according to the rule EN 60601 1 IPX0 Command of execution...

Страница 16: ...that the product shall not be disposed of as domestic waste The user must dispose of scrap equipment by taking it to a recognized centre of recycling of electrical and electronic equipment Appendix B...

Страница 17: ...ctrostatic discharge ESD IEC 61000 4 2 6kV contact 6kV contact Floors should be wood concrete or ceramic tile If floors are covered with synthetic material the relative humidity should be at least 30...

Страница 18: ...th accuracy To assess the electromagnetic environment due to fixed RF transmitters an electromagnetic site survey should be considered If the measured field strength in the location in which the ME EQ...

Страница 19: ......

Страница 20: ......

Страница 21: ...nd warehouse 30030 MARTELLAGO VE Via S Pertini 24 A Tel 0039 041 5401356 Fax 0039 041 5402684 Cod Fisc P IVA IT 00185480274 R E A VE N 120250 M VE001767 e mail iacer iacer it Internet www itechmedical...

Отзывы: