• The charge controller must be easy to remove from the mounting location at any
time.
• The ambient temperature should be between -20 °C and +60 °C to guarantee optimal
operation.
• Do not expose the charge controller to direct sunlight to avoid power losses due to
overheating.
4.2.4 Safety Clearance
Observe the following safety clearance to wall, other devices or objects to ensure
sufficient heat dissipation.
Direction
Safety clearance
Sides
20cm
Top
30cm
Bottom
20cm
5.
MPPT controller Connection
5.1 Safety
Danger!
Danger to life due to high voltage in the solar charge controller.
• Disconnect the PV array using a disconnection unit and secure it against
accidental reactivation.
• Disconnect the circuit breaker and ensure that it cannot be reconnected.
• Ensure that no voltage is present in the system.
Warning:
Risk of injury due to electric shock
。
If all cables with different voltages are routed in parallel, damaged cable
insulations may lead to a short circuit.
• Route all cables separately.
Warning:
Over voltage can destroy the system.
• Use an external over voltage protector in areas with an increased risk of
thunderstorm and lightning.