![I-Panda I-P-SMART2-40A Скачать руководство пользователя страница 21](http://html1.mh-extra.com/html/i-panda/i-p-smart2-40a/i-p-smart2-40a_manual_3105956021.webp)
PV Modules
Utilization Rate
12V/24V/48Vsyste
m
≥99%
Input Characteristics
MPPT Working
Voltage and Range
12V system
DC18V~DC150V
24V system
DC34~DC150V
48V system
DC65~DC150V
Low Voltage Input
Protection Point
12V system
DC16V
24V system
DC30V
48V system
DC60V
Low Voltage Input
Recovery Point
12V system
DC22V
24V system
DC34V
48V system
DC65V
Max DC Voltage
12V/24V/48V
system
DC160V
Input Overvoltage
Protection Point
12V/24V/48V
system
DC150
Input Overvoltage
Recovery Point
12V/24V/48V
system
DC145V
Max. PV Power
12V system
570W
700W
900W
24V system
1130W
1400W
1700W
48V system
2270W
2800W
3400W
Output Characteristics
Selectable Battery
Types (Default type
is GEL battery)
12V/24V/48Vsyste
m
Sealed lead acid, vented, Gel, NiCd battery
(Other types of the batteries also can be defined)
Constant Voltage
12V/24V/48V
system
Please check the charge voltage according to the battery
type form.
Floating Charge
Voltage
12V/24V/48V
system
Over Charge
Protection Voltage
12V system
14.6V
24V system
29.2V
48V system
58.4V
Rated Output
Current
12V/24V/48V
system
40A
50A
60A
Current-limiting
Protection
12V/24V/48V
system
44A
55A
66A
Rate charge current
12V/24V/48V
System
40A
50A
60A
Temperature Factor
12V/24V/48V
system
±0.02%/
℃
Temperature
Compensation
12V/24V/48V
system
14.2V-(The highest temperature-25
℃
)*0.3
Output
12V/24V/48V
200mV