If there is any part missing, please contact your dealer.

3.2 Check for Transport Damage
Check the charge controller for visible external damage, such as cracks in the
enclosure. Contact your dealer if you find any damage.

3.3 Identifying the Charge Controller
You can identify the charge controller by the type label. The type label is in the
enclosure.

4.

Assembly

4.1 Operator

technical personnel;

4.2 Selecting the Mounting Location

4.2.1 Dimensions

L * W * H

270mm*150mm*88mm

4.2.2 Net Weight

Weight

3kg

4.2.3 Ambient Conditions

• The mounting location and method must be suitable for the weight and dimensions.

• Mount on a solid surface.

• The mounting location must be accessible at all times.

Danger:
Danger to life due to fire or explosion.

The charge controller enclosure can become hot during operation.
• Do not mount the charge controller on flammable construction material.
• Do not mount the charge controller near highly flammable materials.
• Do not mount the charge controller in potentially explosive areas.
• Do not expose the charge controller to direct sunlight to avoid power

loss due to overheating.

Caution:
Danger of burn injuries due to hot enclosure parts.

• Mount the charge controller in such a way that it cannot be touched

inadvertently during operation.

Содержание I-P-SMART2-40A

Страница 1: ...Shenzhen I Panda New Energy Technology Science Co Ltd I P SMART2 40A 50A 60A Manual...

Страница 2: ...g 5 4 Assembly 6 5 MPPT controller Connection 7 6 Meaning of LED LCD and function key 10 7 Parameter Setting 12 8 MPPT and PC Connection 13 9 Technical Parameter 18 10 Maintenance and Cleaning 20 11 S...

Страница 3: ...must be stored in the immediate vicinity of the charge controller and must be accessible at all times 1 4 Symbols Used The following types of safety messages and general information appear in this do...

Страница 4: ...roller can become hot during operation Avoid contact during operation And never put any goods onto the equipment under load Caution Radiation is harmful for health Do not stay closer less than 20 cm a...

Страница 5: ...cleaning or working on any circuits connected to the solar charge controller Before using the solar charge controller please read all instructions and cautionary markings on the solar charge controll...

Страница 6: ...chance of short circuits authorized service personnel must use insulated tools when installing or working with this equipment 3 Unpacking 3 1 Device parts checking Object Quantity Description A 1 unit...

Страница 7: ...e mounting location and method must be suitable for the weight and dimensions Mount on a solid surface The mounting location must be accessible at all times Danger Danger to life due to fire or explos...

Страница 8: ...MPPT controller Connection 5 1 Safety Danger Danger to life due to high voltage in the solar charge controller Disconnect the PV array using a disconnection unit and secure it against accidental reac...

Страница 9: ...op is about 1 2 So we suggest the solar charge controller install near PV module in order to save wire and reduce DC loss 5 2 2 The voltage of battery system and types 1 This controller could charge f...

Страница 10: ...r Solar Eagle software It have 6 way to control it ON Mode OFF Mode Time Control Mode PV Volt Ctrl PV Time Ctrl Details please check the Setting 2 How to set the low voltage protection of DC output Th...

Страница 11: ...onnected in right way Step 1 Open the breaker that connect with battery make sure the MPPT controller had been connect with with the battery When all this done the LED and LCD will show some informati...

Страница 12: ...Blue Charging Light Blue when controller start to charge power this light will on LOAD Green Load Light Green when the DC load turn on this load will on UP UP Function Key For check or page up and num...

Страница 13: ...charging state 2 Setting Parameter set 3 Information For check the parameter 6 3 1 The information of LCD display in different menu SMART 2 MPPT LCD INFORMATION Note Chg Cur Charge current If is char...

Страница 14: ...e Control Set the double time to control the DC load output on off Load Off Bat Volt Set the low voltage protection of battery Based on one battery On Off Mode Keep on off state PV Volt Ctrl Could set...

Страница 15: ...n need be set For example Press ESC into main menu Press down to change the page to setting Press ENTER to get in Press DOWN to change to load control Press ENTER to get in Press DOWN to On Off Mode P...

Страница 16: ...overview Get into main interface as following Com Setting Com Get into set the connection of Solar Eagle and PC Setting Get into battery type set and load control set interface...

Страница 17: ...need administrator s pass word 8 2 Then connection of MPPT and Solar Eagle Could connect trough RS 232 COM or TCP IP 8 2 1 Connect through RS232 COM 1 Customer s PC have RS232 connector check the foll...

Страница 18: ...ose COM communication and enter it will automatic connect Step 5 After all these steps the information could be check on Solar Eagle If need to set special parameters please ask our company to accredi...

Страница 19: ...mber of IP address should keep different Like Controller s GATED ADDRESS is 192 168 1 1 IP ADDRESS is 192 168 1 10 then set of PC s GATED ADDRESS is 192 168 1 1 IP ADDRESS is 192 168 1 8 Make sure con...

Страница 20: ...troller and PC in the same LAN and restart controller 8 2 3 Usage of Solar Eagle When Solar Eagle have been connect customer could check and change some parameters If have some special parameters need...

Страница 21: ...0W 1700W 48V system 2270W 2800W 3400W Output Characteristics Selectable Battery Types Default type is GEL battery 12V 24V 48Vsyste m Sealed lead acid vented Gel NiCd battery Other types of the batteri...

Страница 22: ...age Factory set is 10 5 Note set based on 1 battery Communication Features RS232 Communication 12V 24V 48V System Chose COM communication LAN Communication 12V 24V 48V System Set IP and Gate address f...

Страница 23: ...on IP21 Environment Humidity 0 90 RH no condense Altitude 0 3000m Operating Temperature 20 40 Storage Temperature 40 75 Atmospheric Pressure 70 106kPa 10 Maintenance and Cleaning 10 1 Replacing the Th...

Страница 24: ...d is not allowed to down in the device Make the air vent open Carefully remove dirt with a suitable soft brush 11 Storage and waste disposal 10 1 Store the charge controller in a dry place with ambien...

Страница 25: ...use If the problem persists please contact the customer service Please offer the following information Equipment information Model Order No serial number Stickers on the rear plate Detailed descriptio...

Отзывы: