INSTALLATION & OPERATION MANUAL
L500 Series
- 56 -
CHAPTER 10
ENGINE STORAGE
CAUTION
FOR WINTER STORAGE, SEAWATER SHOULD BE DRAINED FULLY
BY LOOSENING THE HEAT EXCHANGER ANODE.
REFER TO CHAPTER 9.
The major consideration in preparing your engine for storage is to protect it from rust, corrosion,
and damage caused by freezing of trapped water.
The following storage procedures should be followed to prepare your engine for out-of-season
storage or prolonged storage (two months or longer and/or winter storage) :
CHECK LIST
• Visual inspection for leaks and damage
• Change engine oil and oil filter
• Replace fuel filter
• Check air filter element and clean if necessary
• Check engine coolant level and top up if necessary
• Check impeller and replace if necessary
• Check anodes and replace if necessary
• Clean the engine
• Flush and drain seawater cooling system
• Fill fuel tank until full and inspect the fuel system
• Remove the battery and store in a cool, dry place