1. Electric parts
It is compressor and motor fan that finally drives after power is supplied. And it is necessary to check the inter-
nal factors like switches, protectors, or lead wires that are needed to reach the compressor and motor fan to
see if their connections are normal and the external factors to see if voltage is normally supplied.
1.1 External factors check
1) Working power and voltage drop
The rated voltage for airconditioner is specified in a workable range.
In order to operate airconditioner normally, it is desirable for the working voltage and minimum. starting voltage
to be within the following chart range.
Especially, just the fact that the voltage when airconditioner is not at work is within the working voltage range is
insufficient, and the voltage is sure to be within the working voltage range by measuring in a operating condi-
tion.
* Usable voltage = Product rating ±10%
2) Electric wire capacity
The electric wire for airconditioner should have an allowable current more than the load current of the circuit
and be able to control the voltage drop by the load current within 2%.
And it should be a thickness capable of keeping the voltage drop by a starting current within -10%, and espe-
cially for an airconditioner of single phase, the voltage drop (Flicker voltage) by the starting currnet be within
about 5%.
A = V1 - V2 : Voltage drop by the starting current of airconditioner (Flicker voltage)
B = V1 - V3 : Voltage drop by the normal running current of airconditioner
In case of using an airconditioner in a low voltage area where power supply voltage is low, especially, the Flicker
voltage due to inadequate wires may cause the fluorescent light to be off or may affect the other electric products.
So, care should be taken to the wiring work.
lnput voltage (V1)
Voltage drop
V
oltage
Time
Starting voltage(V2)
Running voltage(V3)
V1 - V3
X
100
≤
2%(B case)
V1
V1 - V2
X
100
≤
5%(A case)
V1
Air Conditioner Service Manual
63
Содержание HSH-I073NBE
Страница 18: ...Louver Pipes and Power Air Conditioner Service Manual 18 ...
Страница 19: ...Air Conditioner Service Manmual 19 ...
Страница 22: ...Air Conditioner Service Manual WIRING DIAGRAM MODEL HSH I183NBE INDOOR UNIT OUTDOOR UNIT 22 ...
Страница 23: ...Air Conditioner Service Manual WIRING DIAGRAM MODEL HSH I243NBE INDOOR UNIT OUTDOOR UNIT 23 ...
Страница 25: ...Air Conditioner Service Manual WIRING DIAGRAM MODEL HSH L093NDC W HSH L093NDC S INDOOR UNIT OUTDOOR UNIT 25 ...
Страница 26: ...Air Conditioner Service Manual WIRING DIAGRAM MODEL INDOOR UNIT OUTDOOR UNIT 26 ...