Air Conditioner Service Manual
Length (m)
Max Distance
Height (m)
Connection
Pipe
Length (m)
3
Dimension of Package (L/W/H)( mm)
745x550x353
Gas Pipe (mm)
Ф
9.52(3/8)
Outer Diameter
Liquid Pipe (mm)
Φ
6(1/4'')
Gas additional charge(g/m)
20
Refrigerant Charge (kg)
440
Net Weight /Gross Weight (kg)
23.3/25.3
Moisture Protection
IP24
Dimension (W/H/D) ( mm)
600x500x232
Sound Power Level dB (A) (H/M/L)
Sound Pressure Level dB (A) (H/M/L)
50
Permissible Excessive Operating Pressure for
theSuction Side(MPa)
0.65
Permissible Excessive Operating Pressure for the
Discharge Side(MPa)
2.8
Air Flow Volume of Outdoor Unit(m3/h)
1415
Isolation
I
Climate Type
T1
Defrosting Method
Auto defrost
Fan Diameter (mm)
φ
324×119
Fan Type
Axial fan
Rows-Fin Gap(mm)
1-1.8
Fan Motor Capacitor (
μ
F)
2
Fan Motor RLA(A)
0.37
Output of Fan Motor (W)
25
Fan Motor Speed (rpm)
895
Coil length (l) X height (H)Xcoil width (L)
621*462*12.7
Overload Protector
B145-140-141E
Pipe Diameter (mm)
Φ
7
Condenser
Hydrophilic aluminum fin-copper tube
Working Temp Range (ºC)
18-43
Starting Method
Capacitor
Throttling Method
Capillary
QING'AN
Compressor Power Input(W)
780±5%
Compressor RLA(A)
3.8
L.R.A. (A)
19
Outdoorunit
Model of Outdoor Unit
HRH-I073NBE
Compressor Type
Rotary
Compressor Model
YZG-E22RY2
Compressor Manufacturer/trademark
Product Code
/
5
Содержание HSH-I073NBE
Страница 18: ...Louver Pipes and Power Air Conditioner Service Manual 18 ...
Страница 19: ...Air Conditioner Service Manmual 19 ...
Страница 22: ...Air Conditioner Service Manual WIRING DIAGRAM MODEL HSH I183NBE INDOOR UNIT OUTDOOR UNIT 22 ...
Страница 23: ...Air Conditioner Service Manual WIRING DIAGRAM MODEL HSH I243NBE INDOOR UNIT OUTDOOR UNIT 23 ...
Страница 25: ...Air Conditioner Service Manual WIRING DIAGRAM MODEL HSH L093NDC W HSH L093NDC S INDOOR UNIT OUTDOOR UNIT 25 ...
Страница 26: ...Air Conditioner Service Manual WIRING DIAGRAM MODEL INDOOR UNIT OUTDOOR UNIT 26 ...