Wiring mistake -2/2
Case-19
Factor
Major electrical problems(not operating properly) by bad insulations of connecting cables.
Poor electric insulation.
Troubles &
Causes
Defect Details
Guidelines
■
Poor electric insulations of connecting cables between indoor and outdoor.
Insulation break
(Badly insulated or damaged cables)
From outdoor
Cupper pipes
Black
White
Red
To indoor
How to confirm the correct insulations of connecting cables.
(for the troubles be insulation break)
1. Outdoor runs on main electric power's supply.
❒
Short between white and red cables.
2. Fuse melts on compressor's running.
❒
Short between red cable and copper pipe.
3. Fuse melts on main electric power's supply.
❒
Short between black (or white) cable and copper pipe.
4. Main electric braker operates on electric power's supply.
❒
Short between black or white cables.
5. Main electric braker operates after 10~20 min from electric power's supply.
❒
Short between black or white cables.
(Occurs after drainage break into badly insulated parts)
Air Conditioner Service Manual
TCL Air Conditioner Service Manual
99
Содержание HSH-I073NBE
Страница 18: ...Louver Pipes and Power Air Conditioner Service Manual 18 ...
Страница 19: ...Air Conditioner Service Manmual 19 ...
Страница 22: ...Air Conditioner Service Manual WIRING DIAGRAM MODEL HSH I183NBE INDOOR UNIT OUTDOOR UNIT 22 ...
Страница 23: ...Air Conditioner Service Manual WIRING DIAGRAM MODEL HSH I243NBE INDOOR UNIT OUTDOOR UNIT 23 ...
Страница 25: ...Air Conditioner Service Manual WIRING DIAGRAM MODEL HSH L093NDC W HSH L093NDC S INDOOR UNIT OUTDOOR UNIT 25 ...
Страница 26: ...Air Conditioner Service Manual WIRING DIAGRAM MODEL INDOOR UNIT OUTDOOR UNIT 26 ...