Master and Slave Menu Setup
Revision C
Bi-parting Gate Systems
5-3
0
$67(5
$1'
6
/$9(
0
(18
6
(783
Determine which unit will be set up as the Master. The other unit will be set up as the Slave. It doesn’t matter
which unit is which, but you must identify the Master and Slave operators by taking the following steps:
Start by configuring the MASTER unit.
1. At a gate status display, press the MENU button
twice. This accesses the User Menu and the
CLOSE TIMER display appears.
2. Simultaneously, press the OPEN and RESET
buttons to enter the Installer Menu. Release the
buttons and the LEARN LIMITS display
appears which is the first item in the Installer
Menu.
3. Press NEXT until the DUAL GATE display
appears. The factory default setting is 0.
4. Use the SELECT and NEXT buttons to
navigate and change the setting to 2 MASTER.
5. To exit the Installer Menu, press the MENU
button. A gate status appears in the display
indicating you have returned to Run Mode.
Note:
For proper operation, you must set the other
gate operator as SLAVE.
6. Move to the other SlideSmart operator.
7. Using the buttons on the Smart DC Controller,
access the DUAL GATE display through the
Installer Menu.
8. Perform the same steps, 1 through 5, but address
the operator as SLAVE, setting 1.
When the SlideSmart operator has been designated
as the master and the other as slave, the dual-gate
operators will be in constant communication, most
often, in a peer-to-peer relationship. For example,
•
Any control input that is attached to the slave unit
will be recognized by the master once the Installer
Menu is properly configured in both units.
•
A diagnostics log is maintained in each unit, but
both units run and store the errors codes and
diagnostics pertinent to each other.
•
The master unit controls the close timer even if the
timer is set in the slave unit. If a close timer is set in both units, the master unit overrides the slave setting.
127(
If the dual-gate communication stops for whatever reason, (communication wire severed or the
power switch is turned off in one unit), both operators cease to function and an ERROR 4
(Master/Slave Communication Error) appears in the display.
HYSECURITY
GATE CLOSED
OPEN
CLOSE
STOP
MENU
RESET
PREV
NEXT
SELECT
CT 0 (OFF)
CLOSE TIMER
OPEN
CLOSE
STOP
MENU
RESET
PREV
NEXT
SELECT
DG 2 (MASTER)
DUAL GATE
OPEN
CLOSE
STOP
MENU
RESET
PREV
NEXT
SELECT
1. Start at a gate status
display.
2. Access the User
Menu by pressing
MENU twice.
3. Access the Installer
Menu, by
simultaneously
pressing OPEN and
RESET. Release the
buttons.
4. Use NEXT to
navigate to the menu
display. Change the
setting using the
SELECT and NEXT
buttons.
LL 0 (OFF)
LEARN LIMIT
OPEN
CLOSE
STOP
MENU
RESET
PREV
NEXT
SELECT
All manuals and user guides at all-guides.com
Содержание SlideSmart DC 10F
Страница 4: ...All manuals and user guides at all guides com ...
Страница 12: ...All manuals and user guides at all guides com ...