Installing a MagLock or Solenoid Lock
Revision C
Reference
6-3
,QVWDOOLQJD/RFNIRU9'&RU9'&6\VWHPV
To install a lock for 12VDC or 24VDC
systems, take the following steps:
1. Connect a wire between COM on
USER 1 RELAY and a COM terminal
on the Smart DC Controller board. See
Figure 6-2.
2. Connect the power lead from the lock
to the appropriate power spade
(+24VDC or +12VDC)
3. Connect the common wire from the
lock to NC on USER 1 RELAY.
Note:
Connect to NO on USER 1
RELAY if installing a Solenoid lock.
4. Set the User Relay function in the
Installer Menu to RL1 - 6. Refer to
Setting the User Relay Function in the
Installer Menu
.