Installation and Maintenance Manual
21
Smart Touch Controller User Menu Settings for HTG
Initial Power Up
– When power is turned on, the display will disclose the software revision:
Display Revision Number
2s delay
Displays software version Number, ex. [h3.02]
System Data and accessing the User Menu Settings:
If the gate is stopped in normal mode, pressing of the
Menu button
accesses the User Menu. After the
menu button is pressed, the LCD will scroll the system data in the table below. The scrolling display
stops at the close timer setting, which is the beginning of the User Menu. To exit the Menu Mode, the
display must not be blinking, then simply pressing the Menu button will return the display to the Run
Mode and re-enable the controls. The menu mode will also automatically return to the Run Mode if there
is no activity for two minutes.
Data Displayed in Scroll Time
Description
S1 [
SLAu
]
or
[LEAd]
2s
SLAVE Operator or LEAd Operator (master)
S2 [ot 4] Gate type (1-5)
2s
Operator type: 1=HSG, 2=HRG, 3=HVG, 4=HTG
S3 [uC _] UL usage class (1-4)
2s
Installer setting of usage class: type 1-4
S4 [d___] 24VDC Buss Voltage
2s
Actual VDC buss voltage
S5 [CC__] Life cycle counter
2s
High digits of 6 digit life cycle counter
S6 [____] Life cycle counter
2s
Last 4 digits of 6 digit life cycle counter
Read through the options available in the User Menu and the Installer Menu on the next page and you
can see that the functions of this gate operator can be configured to suit most any specific need. Once
you have learned to navigate the menus, as described in #2 on page16, and how to change a menu
setting, the full range of features and choices of the Smart Touch Controller are available to use. The
User Menu contains the basic configuration items and the Installer Menu contains the more advanced
menu items.
User Menu Options
Default
Description
U1
[Ct 0] Close timer setting
0
0 = Close timer off or 1 – 99 seconds
U2
[hC 0] Momentary Close
0
0 = momentary, 1= Constant hold PB required
U3
[ho 0] Momentary Open
0
0 = momentary, 1= Constant hold PB required
U4
[AP 0] AC Power loss function
0
0 – 3 (0 =Type A, 1 = B, 2 = C, 3 = D) See page 47
U5
[ro 0] Radio control option
0
0 = Open only, 1 = Adds close ability when full open
U6
[bF 2] Warn before operate
0
0 =off, 1 = Buzzer alerts 3 seconds in motion,
2 = Buzzer alerts 3 sec 2 seconds in motion
U7
[FA 0] Forced open Alert and
automatic gate reposition
0
0 = off, 1 sound buzzer (2 pulses/sec) if forced
open for more than four seconds, time out in 30 Sec
U8
[dA 0] Drift Closed Alert and
automatic gate reposition
0
0 = off, 1 sound buzzer (2 pulses/sec) if drift closed and
cannot reopen within four seconds.
U9
[PE 0] Photo Eye Align Mode
0
0= off, 1 = on (auto off when close limit triggered)
U10 [CL 0] Clock set (24 hour type)
0
0= display, 1= set mins, 2= set hours, 3= day, 4= month
U11 [Ld 5] LCD Contrast set
5
1 - 9 = Adjusts contrast of the display
U12
[dS 0] Data Log (New Gen only)
0
0 = Std. 1 = Extended (reset to 0 in 24 hr) (V4.xx software)
Note: The Warn before operate buzzer is an accessory item for the HTG operator.
These Notes Refer to the Menu Above:
S1 Appears only if the operator is configured as a master or a slave unit
U1 Close timer setting does not appear when set for constant contact close to function
U4 Power loss function only appears if factory has provided DC type operator
U6 The Warn before operate buzzer is available as an accessory item for the HTG operator.
Содержание HTG 320-2
Страница 18: ...Installation and Maintenance Manual 10 Components of the Barrier Arm Gate Operator ...
Страница 21: ...Installation and Maintenance Manual 13 46 ...
Страница 22: ...Installation and Maintenance Manual 14 46 ...
Страница 23: ...Installation and Maintenance Manual 15 ...
Страница 43: ...Installation and Maintenance Manual 35 E95 ...
Страница 48: ...Installation and Maintenance Manual 40 24 hr 7 day Timer Connection to Smart Touch Controller ...
Страница 56: ...Installation and Maintenance Manual 48 D C POWER BATTERY PACK 2 BATTERY 110AH 30 H X 30 W X 12 D ...
Страница 57: ...Installation and Maintenance Manual 49 24V 110A H BATTERY POWER SUPPLY FOR DC OPERATORS ...
Страница 59: ...Installation and Maintenance Manual 51 ...
Страница 60: ...Installation and Maintenance Manual 52 Parts Breakout ...
Страница 61: ...Installation and Maintenance Manual 53 Parts Breakout ...
Страница 62: ...Installation and Maintenance Manual 54 Parts Breakout AC Pumps MX000234 HVABY 000 CRT ...
Страница 63: ...Installation and Maintenance Manual 55 Parts Breakout DC Pumps MX000234 HVABY 000 CRT ...
Страница 64: ...Installation and Maintenance Manual 56 Parts Breakout ...
Страница 67: ...Installation and Maintenance Manual 59 Smart Touch Controller Connections ...
Страница 68: ...Installation and Maintenance Manual 60 Quick StrongArm Brake Valve adjustment Procedure ...