4. Operation
TSα Series User Manual 91
4.11
Robot and Program maintenance Screen
Turn power on with pressing
NO
Screen
Mode
Order Default/Setting
Description
Etc
- Traverse Limit Range
1
Limit for
Traverse
+ Traverse Limit Range
2
No Down
Range
No Down Range
3
In Mold
Traverse
Limit
Traverse Limit in Mold
±20mm
①
NoSet
(=default)
Press
Enter
will
not
current position to origin
point
4
Origin
②
Set
Press Enter will change
current position to Origin
Point
①
NoUse
(=default)
Not In Usa
5
Safety
Use
②
Use
Ultra Sound Safety
①
NoUse
(=default)
Auto Input Signal from
IMM is not required
6
Auto
Input
②
Use
Auto Input Signal from
IMM is required for Auto
Mode.
①
Use
(=default)
Not sending Take Out Fail
signal to IMM
7
Origin NoSet
Safety NoUse
AutoInp NoUse
TKOFail NoUse
Take Out
Fail
②
NoUse
Send Signal to IMM when
robot can take out the part
or sprue
①
NoUse
(=default)
IMM E-stop Input don
’
t
activate Robot E-Stop
8
IMM
Alarm
②
Use
IMM
E-Stop
activate
Robot E-Stop
Содержание TS-200DI
Страница 2: ......
Страница 14: ...xii...
Страница 15: ...xiii...
Страница 19: ......
Страница 20: ......
Страница 21: ...1 Introduction...
Страница 22: ......
Страница 28: ......
Страница 29: ...2 Before Operation...
Страница 30: ......
Страница 41: ...3 START UP STOP...
Страница 42: ......
Страница 47: ...4 OPERATION...
Страница 48: ......
Страница 110: ...4 Operation 90 TS Series User Manual 4 10 Change Language Press and at the same time change Korean English Chinese...
Страница 114: ......
Страница 115: ...5 Follow Up...
Страница 116: ......
Страница 126: ......
Страница 127: ...6 Error...
Страница 128: ......
Страница 134: ......
Страница 135: ...Appendix...
Страница 136: ......
Страница 139: ...Appencix TS Series User Manual 119 B 2 TS 300DI dimension Unit mm Type A B 300SI 1005 58 300DI 875 188...
Страница 141: ...Appencix TS Series User Manual 121 C 2 TS 300DI Unit mm Type A B C D 300SI 1173 58 1273 235 300DI 1043 20 1243 280...
Страница 143: ......