© 2022 HyQuest Solutions
74
Configuration
5. Leave the Registers list blank.
6. Click the
SEND CONFIG
button to commit this to the iRIS.
7. Click the
RETRIEVE CONFIG
button to obtain the dynamically created indices.
8. Navigate to the
SENSORS
section of the configuration tree and click the
+ ADD SENSOR
branch.
9. In the newly created sensor enter the following:
Name:
Wind Speed
Source:
Frequency 1
Multiplier:
0.01
Units:
m\s
10. Click the
+ ADD SENSOR
branch and in the newly created sensor enter the following:
Name:
Wind Direction
Source:
Analogue Input 1
Multiplier:
71.8
Содержание iRIS Under Cover