SETUP
1
powermax30
Operator Manual
3-5
1. Strip back the cord insulation to separate wires 3, 4, and 5.
2. Remove each wire’s insulation in order to make good contact with the plug terminals.
3. Make the connections, reinstall the outer shell and cord grip, and tighten the cord grip’s
screws. Screws should be snug, but not overly tight.
230 V plug
To line 1 terminal (brass)
To line 2 terminal (brass)
To ground terminal (green)
Outer shell
Cord grip
1
2
3
4
5
6
1
2
3
4
5
6
Power cord for CE power supplies
The CE power supplies are shipped without a plug on the power cord. To operate at 230 V, obtain
the correct plug and have it installed by a licensed electrician as shown below.
PMX30_OM_03.qxp:PMX30_OM_03 10/7/09 12:44 PM Page 3-5