MAINTENANCE AND PARTS
1
powermax30
Operator Manual
5-17
15. Replace the endcap.
16. Replace the Nomex barrier and slide the cover back onto the power supply. Position the
handle over the holes in the top of the cover, then use the 2 screws to secure the cover.
17. Reconnect the electrical power and the gas supply.
L
Brown wire
N
Blue wire
Replace the power cord (CE)
1. Turn OFF the power, disconnect the power cord, and disconnect the gas supply.
2. Remove the cover from the power supply and remove the Nomex barrier from in front of the
power board.
3. Remove the rear endcap.
4. The power cord has a brown wire and a blue wire that connect to the power switch and a
green and yellow ground wire that connects to the heatsink.
Carefully pull the connector for the blue wire away from the power switch to disconnect it. You
can use needlenose pliers or a straight screwdriver to ease it out, if necessary.
Single phase
L
Brown
N
Blue
PE
Green/yellow
PMX30_OM_05.qxp:PMX30_OM_05 10/7/09 12:46 PM Page 5-17
Содержание Powermax30 AIR
Страница 12: ...TABLE OF CONTENTS viii powermax30 Operator Manual PMX30_OM_FM qxp PMX30_OM_FM 10 7 09 12 43 PM Page viii ...
Страница 24: ...1 12 Hypertherm 11 08 SAFETY ...
Страница 36: ...11 08 1a 12 Hypertherm SÉCURITÉ ...
Страница 48: ...11 08 SEGURIDAD 1b 12 Hypertherm ...
Страница 54: ...SPECIFICATIONS 2 6 powermax30 Operator Manual PMX30_OM_02 qxp PMX30_OM_02 qxd 10 7 09 12 44 PM Page 2 6 ...
Страница 74: ...OPERATION 4 12 powermax30 Operator Manual PMX30_OM_04 qxp PMX30_OM_04 10 7 09 12 45 PM Page 4 12 ...
Страница 98: ...MAINTENANCE AND PARTS 5 24 powermax30 Operator Manual PMX30_OM_05 qxp PMX30_OM_05 10 7 09 12 46 PM Page 5 24 ...