operation
powermax
45
Operator Manual
4-3
45
30
40
A
mperage adjustment knob
Set this knob to the gas test position (fully counter-clockwise) before adjusting the gas pressure with
the pressure regulator knob on the top of the power supply. Once the gas pressure is set, turn the knob
clockwise to set the output amperage. The torch will not fire when the knob is in gas-test position.
Mode switch and leds
The mode switch can be set in one of three positions:
• Continuous pilot arc to cut expanded metal or grate (top).
• Non-continuous pilot arc to cut metal plate (middle).
• Gouging (bottom).
After you change the mode switch, verify that the gas pressure is still set correctly. Different modes of
cutting require different pressure settings.
Rear controls
200–240 V CSA / 230 V Ce
400 V Ce / 480 V CSA
I
O
I
O
ON (I)/Off (O) power switch
Activates the power supply and its control circuits.
Operate the Powermax45
Follow the steps below to begin cutting or gouging with the Powermax45.
Connect the electrical power and gas supply
Plug in the power cord and connect the gas supply line. For more information about the electrical requirements and the
gas supply requirements of the Powermax45, see the
section.
Содержание POWERMAX 45
Страница 1: ...45 Plasma arc cutting system Operator Manual 805780 Revision 2 ...
Страница 6: ......
Страница 10: ...Table of Contents iv powermax45 Operator Manual ...
Страница 30: ...Power supply setup 2 8 powermax45 Operator Manual ...
Страница 74: ...operation 4 16 powermax45 Operator Manual ...
Страница 84: ...Maintenance and Repair 5 10 powermax45 Operator Manual ...