power supply setup
powermax
45
Operator Manual
2-3
Position the power supply
Locate the Powermax45 near an appropriate 200–240 volt power receptacle for CSA or CE 1-phase power supplies,
a 400 volt receptacle for 3-phase CE power supplies, or a 480 volt receptacle for 3-phase CSA power supplies. The
Powermax45 has a 3 m (10-foot) power cord. Allow at least 0.25 m (10 inches) of space around the power supply for
proper ventilation.
Prepare the electrical power
The maximum output voltage will vary based on your input voltage and the circuit’s amperage. Because the current
draw varies during startup, slow-blow fuses are recommended as shown in the following chart. Slow-blow fuses can
withstand currents up to 10 times the rated value for short periods of time.
Voltage configurations
The following chart shows the maximum rated output for typical combinations of input voltage and amperage.
Acceptable input voltages can be ±10% of the values given below.
CAUTION
Protect the circuit with appropriately sized time-delay (slow-blow) fuses and a line-disconnect switch.
Model Input voltage Phase Rated output
Input
current at
6 kw output
Input
current
during arc
stretch
Recommended
slow-blow fuse
size
CSA
200–240 VAC
1
45 A, 132 V
34–28 A
55–45 A
50 A
208 VAC
1
45 A, 132 V
33 A
54.5 A
50 A
480 VAC
3
45 A, 132 V
8.5 A
12 A
15 or 20* A
CE
200–240 VAC
1
45 A, 132 V
34–28 A
55–45 A
35 or 50* A
400 VAC
3
45 A, 132 V
10 A
15.5 A
15 or 20* A
CE/CCC
220 VAC
1
45 A, 132 V
31 A
53 A
35 or 50* A
380 VAC
3
45 A, 132 V
11 A
14 A
15 A
* Use the higher amperage fuse for applications that require a long arc stretch.
Содержание POWERMAX 45
Страница 1: ...45 Plasma arc cutting system Operator Manual 805780 Revision 2 ...
Страница 6: ......
Страница 10: ...Table of Contents iv powermax45 Operator Manual ...
Страница 30: ...Power supply setup 2 8 powermax45 Operator Manual ...
Страница 74: ...operation 4 16 powermax45 Operator Manual ...
Страница 84: ...Maintenance and Repair 5 10 powermax45 Operator Manual ...