66
MAXPRO200
Instruction Manual 807700 Revision 1
Installation
Fill the power supply with coolant
The system will take 14.2 liters to 17.0 liters (3.75 to 4.5 gallons) of coolant depending on the length of the torch leads.
1.
Add coolant to the power supply until the tank is full.
2.
Turn ON the power supply, then press and
release the amps selector knob as many times as
needed until the flow symbol is selected. The flow
rate will be shown in the three digit display. There
is a 45 second delay before the system will report
a low coolant flow error. If the flow rate has not
reached 1.9 liters per minute (lpm) (0.5 gallons
per minute [gpm]) the system will turn off the
pump.
3.
If the system displays an error, turn OFF the power to the
system and add coolant to the tank until it is full again.
Repeat steps 2 and 3 until no error is displayed.
4.
Add coolant to the power supply until the tank is
full and replace the filler cap.