MAX200 SETUP
3f-6
CommandTHC for X-Y Table
Instruction Manual
7
Figure 3f-3 MAX200 interface cable – part number and signal list
Part number
Description
Length
123358
MAX200 Power Supply Interface Cable
6 ft./1.8 m
1X6
Power
Plasma
Supply
Interface
Signal Name
Color
End (1X6)
End
Function
Hold I/O –
Black
5
J4-6
(Optional)
Hold Ignition (I/O) signal used for preflow
Hold I/O +
White
1
J4-5
during IHS. Also used by power unit to synchronize
Drain
Drain
10
operation of multiple torch installations. Output signal.
Plasma Start –
Black
9
Relay
Plasma Start signal maintained during plasma cut. If
Plasma Start +
Green
15
Relay
signal is lost, system must be restarted. Output signal.
Drain
Drain
14
Arc Transfer (Delayed) –
Black
31
J3-2
Arc Transfer signal. Contact closes after arc transfer and
Arc Transfer (Delayed) +
Red
36
J3-1
pierce delay (set on power supply front panel).
Drain
25
Dry closure. Input signal.contact
Plasma interface assembly other J3 and J4 connection points:
• J3-5 (+) and J3-6 (–) – Alternate Nozzle Contact. An optically isolated signal that indicates nozzle is in ohmic contact with work.
Ohmic contact is represented by a logic 1.
• J3-7 through J3-12 – Reserved for future use.
• J3-13 and J3-14 – Protective earth ground.
• J4-7 and J4-8 –
Pierce Complete signal used by power unit to time transition from pierce gas flow to cut gas flow. User enters this
time delay into THC. Output signal.
• J4-9 through J4-14 – Reserved for future use.
Содержание Command THC
Страница 61: ...SETUP CommandTHC for X Y Table Instruction Manual 3 7 5 Blank...
Страница 81: ...HD3070 SETUP CommandTHC for X Y Table Instruction Manual 3a 1 5 Section 3a HD3070 SYSTEM INTERCONNECTIONS...
Страница 88: ...HT2000 SETUP CommandTHC for X Y Table Instruction Manual 3b 1 6 Section 3b HT2000 SYSTEM INTERCONNECTIONS...
Страница 95: ...HT2000LHF SETUP CommandTHC for X Y Table Instruction Manual 3c 1 5 Section 3c HT2000LHF SYSTEM INTERCONNECTIONS...
Страница 102: ...HT4001 SETUP CommandTHC for X Y Table Instruction Manual 3d 1 5 Section 3d HT4001 SYSTEM INTERCONNECTIONS...
Страница 108: ...MAX100 SETUP CommandTHC for X Y Table Instruction Manual 3e 1 5 Section 3e MAX100 SYSTEM INTERCONNECTIONS...
Страница 113: ...MAX200 SETUP CommandTHC for X Y Table Instruction Manual 3f 1 6 Section 3f MAX200 SYSTEM INTERCONNECTIONS...
Страница 126: ...HT4400 SETUP CommandTHC for X Y Table Instruction Manual 3h 1 5 Section 3h HT4400 SYSTEM INTERCONNECTIONS...
Страница 135: ...HPR SETUP CommandTHC for X Y Table Instruction Manual 3i 1 9 Section 3i HPR SYSTEM INTERCONNECTIONS...
Страница 148: ...HPR SETUP 3i 14 CommandTHC for X Y Table Instruction Manual Figure 3i 14 Ohmic contact wire connection B B 11...
Страница 149: ...HSD130 SETUP CommandTHC for X Y Table Instruction Manual 3j 1 11 Section 3j HSD SYSTEM INTERCONNECTIONS...
Страница 188: ...MAINTENANCE CommandTHC for X Y Table Instruction Manual 5 15 6 Figure 5 7 Control board...
Страница 192: ...PARTS LIST CommandTHC for X Y Table Instruction Manual 6 3 10 Figure 6 2 THC control module interior...
Страница 220: ...CommandTHC for X Y Table Instruction Manual...