Power
Plasma
Supply
CNC
Interface
Signal Name
Color
End (1X6)
End
End
Function
Hold –
Black
5
Not
J4-6
(Optional)
Hold Ignition (I/O) signal used for preflow
Hold +
White
1
Connected
J4-5
during IHS. Also used by power unit to synchronize
Drain
Drain
10
operation of multiple torch installations. Output signal
Plasma Start –
Black
9
Not
J4-4
Plasma Start signal maintained during plasma cut. If
Plasma Start +
Blue
15
Connected
J4-3
signal is lost, system must be restarted. Output signal.
Drain
Drain
14
Arc Transfer –
Black
31
Not
J3-2
Arc Transfer signal. Contact closes after arc transfer
Arc Tr
Red
36
Connected
J3-1
and pierce delay (set on power supply front panel).
Drain
Drain
25
Dry contact closure. Input signal.
Emergency Stop
Black
28
28
Not
Emergency Stop
Green
33
33
Connected
Drain
Drain
27
27
Arc Voltage
Black
32
32
Not
These signals connect to the CNC. Refer to HT4001
Arc Voltage
Yellow
37
37
Connected
Instruction manual for signal information.
Drain
Drain
26
26
Spare
Black
16
16
Not
Spare
Green
17
17
Connected
Drain
Drain
18
18
HT4001 SETUP
3d-6
CommandTHC for X-Y Table
Instruction Manual
7
Figure 3d-3 HT4001 interface cable – part number and signal list
Part number
Description
Length
123330
HT4001 Power Supply Interface Cable
6 ft./1.8 m
Shaded area indicates plasma interface assembly connections.
Plasma interface assembly other J3 and J4 connection points:
• J3-5 (+) and J3-6 (–) – Alternate Nozzle Contact. An optically isolated signal that indicates nozzle is in ohmic contact with work.
Ohmic contact is represented by a logic 1.
• J3-7 through J3-12 – Reserved for future use.
• J3-13 and J3-14 – Protective earth ground.
• J4-1 (+) and J4-2 (–) – Available 24 VDC, 500 mA maximum
• J4-7 and J4-8 – Pierce Complete signal used by power unit to time transition from pierce gas flow to cut gas flow. User enters this
time delay into THC. Output signal.
• J4-9 through J4-14 – Reserved for future use.
Содержание Command THC
Страница 61: ...SETUP CommandTHC for X Y Table Instruction Manual 3 7 5 Blank...
Страница 81: ...HD3070 SETUP CommandTHC for X Y Table Instruction Manual 3a 1 5 Section 3a HD3070 SYSTEM INTERCONNECTIONS...
Страница 88: ...HT2000 SETUP CommandTHC for X Y Table Instruction Manual 3b 1 6 Section 3b HT2000 SYSTEM INTERCONNECTIONS...
Страница 95: ...HT2000LHF SETUP CommandTHC for X Y Table Instruction Manual 3c 1 5 Section 3c HT2000LHF SYSTEM INTERCONNECTIONS...
Страница 102: ...HT4001 SETUP CommandTHC for X Y Table Instruction Manual 3d 1 5 Section 3d HT4001 SYSTEM INTERCONNECTIONS...
Страница 108: ...MAX100 SETUP CommandTHC for X Y Table Instruction Manual 3e 1 5 Section 3e MAX100 SYSTEM INTERCONNECTIONS...
Страница 113: ...MAX200 SETUP CommandTHC for X Y Table Instruction Manual 3f 1 6 Section 3f MAX200 SYSTEM INTERCONNECTIONS...
Страница 126: ...HT4400 SETUP CommandTHC for X Y Table Instruction Manual 3h 1 5 Section 3h HT4400 SYSTEM INTERCONNECTIONS...
Страница 135: ...HPR SETUP CommandTHC for X Y Table Instruction Manual 3i 1 9 Section 3i HPR SYSTEM INTERCONNECTIONS...
Страница 148: ...HPR SETUP 3i 14 CommandTHC for X Y Table Instruction Manual Figure 3i 14 Ohmic contact wire connection B B 11...
Страница 149: ...HSD130 SETUP CommandTHC for X Y Table Instruction Manual 3j 1 11 Section 3j HSD SYSTEM INTERCONNECTIONS...
Страница 188: ...MAINTENANCE CommandTHC for X Y Table Instruction Manual 5 15 6 Figure 5 7 Control board...
Страница 192: ...PARTS LIST CommandTHC for X Y Table Instruction Manual 6 3 10 Figure 6 2 THC control module interior...
Страница 220: ...CommandTHC for X Y Table Instruction Manual...