12
ArcGlide THC Replacement Parts
Field Service Bulletin 806560
2 – Replacing ArcGlide parts
Accessing ArcGlide parts
The following procedures provide the initial steps for replacing parts in each of the ArcGlide modules:
Accessing lifter parts
1.
Turn OFF power to the lifter and disconnect the power cable.
2.
Remove the lifter from the gantry.
3.
Remove the front of the lifter motor enclosure:
a.
Remove the 4 screws on the front of the enclosure and set them aside.
b.
Remove the 3 connectors for the switches and LED from the front cover on the lifter interface board.
Accessing control module parts
1.
Turn OFF power to the control module and disconnect the power cable and other cables connected to the front
panel.
2.
Remove the control module from the cutting table.
3.
Remove the 6 screws from the rear panel and set them aside.
4.
Fold the rear panel down from the enclosure and lay it flat.
Accessing HMI parts
1.
Turn OFF power to the HMI and disconnect the power and HMI cables.
2.
Remove the 6 screws from the rear panel and set them aside.
3.