Pump wire not damaged 
 

(check closely at mount points and where wire enters frame) 

Pneumatic Spray 
System Tubing 

No leaks in tubing when spraying at max pressure 

Tubing clean of chemical residue  

Nozzle Body 

No leaks when spraying at max pressure 

No cracks in plastic nozzle body 

Internal filter clean and undamaged  

Two 3 Gallon Tanks 

No leaks when tank is full (check tank outlet nipple and bottom 
cap) 

No cracks or damage to plastic  

40 mm Carbon Fiber 
Tubes (Arms) 

No visible cracks in carbon fiber tubes 

All screws tight and rust free  

Arm Elbow Joint 

5 mm pin bolt EXTREMELY tight (check torque) 

No cracks in composite housing  

All screws tight and rust free 

Aluminum Landing 
Gear and Mounts   

No visible cracks or incorrect bends in aluminum legs frame. 
Drone does not wobble when sitting on landing gear 

All screws tight and rust free  

Plastic Guard  

Guard fastener screws tight and rust free  

No large cracks or visible damage  

Internal Components  

Take off plastic shell top: inspect inside center frame for damage 

All connectors plugged in tight  

No loose dangling wires 

No signs of damaged components or electrical shorts  

Battery Trays 

All screws on inside and outside of trays tight and rust free 

Battery connector on drone side clean on inside and all screws 
tight and rust free  

Batteries  

Battery case does not have dents, connector wires do not show 
wear or fray 

Threaded Arm Clamp 

No cracks in plastic 

Threads still hold tight  

Micro USB Connector 

Clean and free of debris inside connector 

Not loose in housing 

Rubber cap in place  

Flowmeter Filters 

No cracks in plastic housing 

No leaks from filter  

Filter mesh clean  

Top Plastic Covers 

No cracks or other visible damage on plates 

All screws tightened to listed torque  

All unnamed fasteners  - 

All tightened to listed torque  

 

 

 

Содержание AgroDrone AG-122

Страница 1: ...AgroDrone Spray System AG 122 Maintenance Manual V2 2...

Страница 2: ...iew 3 Description 4 Daily Maintenance Checklist 6 Maintenance Schedule 7 Inspection Schedule 7 Inspection Criteria 8 Safety 10 Safe Maintenance Guidelines 10 Warning Signs 10 Ground Testing 11 When to...

Страница 3: ...al 2020 Hylio Inc All Rights Reserved 3 Component Identification Overview There are 19 components on the AG 122 which must be identified excluding the two plastic 3 Gallon Tanks and carbon fiber tubes...

Страница 4: ...oint to secure arm during setup n a n a n a 7 Nozzle Body Dual Nozzle body assembly 5 2 5 mm hex 1 2 8 Battery 1 16k mah battery with AS150 U connector n a n a n a 9 Battery 2 16k mah battery with AS1...

Страница 5: ...Removable reusable 80 mesh screen filter in front of flowmeter n a n a n a Center Plastic Cover Small plastic shell covering the flight controller between the two tanks 6 2 5 mm hex 0 75 Top Plastic...

Страница 6: ...filters from nozzle bodies soak in water and clean STEP 2 HARDWARE MAINTENANCE 5 Remove RFD antenna 6 Check for leaks in spray system 7 Inspect GPS bases Radar mount motors drone base flowmeter filte...

Страница 7: ...form an inspection of all parts before resuming operation Part Flight Hours Propeller CCW CW 5 Rotor CCW CW 10 Ground Station Link Radio Antenna 5 GPS 5 GPS Mast 5 Altitude Detection Radar 10 Flowmete...

Страница 8: ...powered on GPS secured straight and tight to mast Double sided tape OK GPS housing and wire not damaged check closely at mount points and where wire enters frame Acceptable GPS accuracy performance GP...

Страница 9: ...me Drone does not wobble when sitting on landing gear All screws tight and rust free Plastic Guard Guard fastener screws tight and rust free No large cracks or visible damage Internal Components Take...

Страница 10: ...oms They are indicators of a potential problem 1 Smell or appearance of electrical smoke from center frame or motors This occurs when there is an electrical short in the system 2 Visual wear on any wi...

Страница 11: ...at 0 5 gallon per minute time how long it takes for tank to empty It should take 4 minutes If time is off by over 5 recalibrate flowmeter 6 While spraying check for any leaks in the spray system 7 Ch...

Страница 12: ...l noises Check the drone appears to fly stable 7 As the drone descends to the mission area check that it yaws to face the mission line direction within acceptable error recalibrate compass if not 8 Ch...

Отзывы: