background image

 

Hylio Agrodrone (AG-122) Maintenance Manual   

 
 
 

©2020 Hylio Inc. All Rights Reserved

 

8

 

  

Inspection Criteria  

 

If the part does NOT pass the listed criteria upon inspection, replace/repair part immediately. As 
a part of the inspection for each part, check for tightness of all fasteners listed for that part in the 
component identification description. Check for tightness to the listed torque.  

 

Part 

Inspection Criteria   

Propeller (CCW/CW) 

No cracks or chips larger than 0.1-inch radius  

Propeller blade level with arm  

M3x12 mount screws tight and rust free 

10 mm lug bolts tight and rust free  

Rotor (CCW/CW) 

No rattling or scratching noise when spun by hand  

No large dents or cracks in rotor housing  

LED mount screws tight  

Rotor guard mount screws tight  

Ground Station Link 
Radio Antenna  

Antenna casing structurally intact 

Antenna screwed in tight to antenna mount  
 

(comes loose often) 

Antenna mount screws tight and rust free   

GPS 

Correct LED indicator colors when powered on 

GPS secured straight and tight to mast (Double sided tape OK)  

GPS housing and wire not damaged  
 

(check closely at mount points and where wire enters frame) 

Acceptable GPS accuracy performance  

GPS does not frequently give errors in AgroSol  

GPS Mast 

No cracks in material  

All screws tight and rust free  

Altitude Detection 
Radar 

Radar housing intact  

Radar wire not damaged 
 

(check closely at mount points and where wire enters frame) 

Unit does not heat up when powered on  

Acceptable altitude readouts in AgroSol  

Flowmeter Units 

Flowmeter housing intact 

Acceptable flowrate readouts in AgroSol  

Flowmeter wire not damaged  
 

(check closely at mount points and where wire enters frame) 

Flowmeter Accuracy  

Flowrate performance during flight (gal/ac output) should be 
within 2%, or 5% in the worst case  

Set a constant test flowrate and measure output over 1 minute 
using a graduated cylinder, actual flowrate should match desired 

If flowrate is not to desired accuracy, perform the flowmeter 
calibration as described in the software manual  

Pumps 

Pump housing intact  

Acceptable maximum pump pressure performance  
 

(maximum pressure output will decline over time) 

Содержание AgroDrone AG-122

Страница 1: ...AgroDrone Spray System AG 122 Maintenance Manual V2 2...

Страница 2: ...iew 3 Description 4 Daily Maintenance Checklist 6 Maintenance Schedule 7 Inspection Schedule 7 Inspection Criteria 8 Safety 10 Safe Maintenance Guidelines 10 Warning Signs 10 Ground Testing 11 When to...

Страница 3: ...al 2020 Hylio Inc All Rights Reserved 3 Component Identification Overview There are 19 components on the AG 122 which must be identified excluding the two plastic 3 Gallon Tanks and carbon fiber tubes...

Страница 4: ...oint to secure arm during setup n a n a n a 7 Nozzle Body Dual Nozzle body assembly 5 2 5 mm hex 1 2 8 Battery 1 16k mah battery with AS150 U connector n a n a n a 9 Battery 2 16k mah battery with AS1...

Страница 5: ...Removable reusable 80 mesh screen filter in front of flowmeter n a n a n a Center Plastic Cover Small plastic shell covering the flight controller between the two tanks 6 2 5 mm hex 0 75 Top Plastic...

Страница 6: ...filters from nozzle bodies soak in water and clean STEP 2 HARDWARE MAINTENANCE 5 Remove RFD antenna 6 Check for leaks in spray system 7 Inspect GPS bases Radar mount motors drone base flowmeter filte...

Страница 7: ...form an inspection of all parts before resuming operation Part Flight Hours Propeller CCW CW 5 Rotor CCW CW 10 Ground Station Link Radio Antenna 5 GPS 5 GPS Mast 5 Altitude Detection Radar 10 Flowmete...

Страница 8: ...powered on GPS secured straight and tight to mast Double sided tape OK GPS housing and wire not damaged check closely at mount points and where wire enters frame Acceptable GPS accuracy performance GP...

Страница 9: ...me Drone does not wobble when sitting on landing gear All screws tight and rust free Plastic Guard Guard fastener screws tight and rust free No large cracks or visible damage Internal Components Take...

Страница 10: ...oms They are indicators of a potential problem 1 Smell or appearance of electrical smoke from center frame or motors This occurs when there is an electrical short in the system 2 Visual wear on any wi...

Страница 11: ...at 0 5 gallon per minute time how long it takes for tank to empty It should take 4 minutes If time is off by over 5 recalibrate flowmeter 6 While spraying check for any leaks in the spray system 7 Ch...

Страница 12: ...l noises Check the drone appears to fly stable 7 As the drone descends to the mission area check that it yaws to face the mission line direction within acceptable error recalibrate compass if not 8 Ch...

Отзывы: