Page 30
8.3 Removing and Cleaning the Steam Cylinder
Warning:
Please follow the detailed instructions in these operat-
ing in structions! The unit is only to be se
rviced by qualified,
authorized personnel. Note the warnings and safety notes in the
operating instru ctions. F ailure to ob serve warnings a nd safety
notes may result in injury, serious injury or death, and/or dam-
age to the unit. The steam cylinder may still be hot wh en you
begin maintenance work. Handle carefully!
Warning:
Both the clamps that fix the steam cylinder halves and
the electrodes have sharp edges and angles that possibly could
lead to cut injuries.
Disassembly
»
Switch on the unit by the main switch. The humidifier
runs the pump for a few seconds. The purpose of this is
to check that the system is operating properly.
»
Drain residual water in the cylinder.
»
Units with Basic, Comfort or Comfort Plus control elec-
tronics:
»
Press the on/off control swith in position „II“.
»
Units with Comfort or Comfort Plus control electronics:
»
Press the Softwarekeys
and
simultane-
ously longer than 5 seconds.
»
Open and remove cover.
»
Disconnect the steam generator from the power supply.
Control switch OFF and remove safety fuse F1.
»
Check that unit is without power.
»
Unscrew and remove the steam nozzle (1).
»
Unplug the electrodes (4).
»
Unplug the sensor electrode (10).
»
Remove adapter (2) between steam cylinder and steam
nozzle (1).
Содержание MiniSteam MS 10
Страница 1: ...Electrode Steam Humidifier MiniSteam MS ENU MS EN Manual...
Страница 16: ...Page 16 5 1 1 Fitting measures Wall Distances mm 150...
Страница 18: ...Page 18 5 3 Unit Dimensions Water inlet Waste water connection Cable entries...
Страница 39: ...Page 39 10 EC Declaration of Conformity...
Страница 45: ...Page 45 15 View of housing...
Страница 46: ...12 2004...