Page 34
8.4.2 Uneven Electrode Lengths
In most case, the longer e lectrode(s) will not be supplied with
electricity for a time. Therefore they will not wear. The cause of
the problem, such as a tripped circuit breaker, can be repaired.
However, since the sh orter electrode(s) have a greater specific
load, the electrodes continue to wear unevenly.
Note:
Replace electrodes with significantly uneven wear. Check
the po wer sup ply (breaker, volt age drop) . Also see ele ctronic
operation, Section "Malfunctions."
8.5 Replacing Electrodes
remove electrode
remove handnut
insert electrode
mount correctly
1=shaft seal, 2=brass ring
3=O-ring
fasten handnut hand-tight,
L1=black, L2=red,
L3=grey, B1=grey