13
WARNING:
If you do not follow these instructions exactly, a fire or explosion may result with property
damage, personal injury, or loss of life.
OPERATING INSTRUCTIONS
Honeywell VR8200
Natural or Propane Gas
A. Before Operating smell all around the appliance area
for gas. Be sure to smell next to the floor because
some gas is heavier than air and will settle on the
floor.
What to do if you smell gas:
• Do not try to light any appliance.
• Do not touch any electrical switch. Do not use any
phone in your building.
• Immediately call your gas supplier from a neigh-
bor's phone. Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire
department.
B. Use only your hand to push in or turn the gas control
knob, never use tools. If the knob will not push in or
turn by hand, don't try to repair it; call a qualified ser-
vice technician. Force or attempted repair may result
in a fire or explosion.
C. Do not use this appliance if any part has been under
water. Immediately call a qualified service technician
to inspect the appliance and to replace any part of
the control system and any gas control which has
been under water.
1.
STOP!
Read the safety information above.
2.
Set the thermostat to lowest setting.
3.
Turn off all electric power to the appliance.
4.
Remove control access panel (if applicable).
5.
Rotate gas control knob clockwise to "OFF".
6.
Wait five (5) minutes to clear out any gas. Then
smell for gas, including near the floor. If you smell
gas,
STOP!
Follow "A" in the safety information
above. If you don't smell gas, go to next step.
7.
Remove the pilot access panel located below and
behind the gas control unit (if applicable).
8.
Find pilot — follow metal tube from gas control. The
pilot is between the two burner tubes behind the
pilot access panel (if applicable).
9.
Turn gas control knob counterclockwise to "PILOT".
10. Push down and hold the red button next to the con-
trol knob. Immediately light the pilot with a match.
Continue to hold the red button down for about one
(1) minute after the pilot is lit. Release button and it
will pop back up. Pilot should remain lit. If it goes
out, repeat steps 5 through 10.
• If button does not pop up when released, stop
and immediately call your service technician or
gas supplier.
• If the pilot will not stay lit after several tries, turn
the gas control knob to "OFF" and call your
service technician or gas supplier.
11. Replace pilot access panel.
12. Turn gas control knob counterclockwise to "ON".
13. Replace control access panel (if applicable).
14. Turn on all electric power to the appliance.
15. Set thermostat to desired setting.
INLET
GAS CONTROL KNOB
SHOWN IN "OFF" POSITION
GAS
ON
OFF
RESET BUTTON
PILOT
CONTINUOUS PILOT – HONEYWELL VR8200
Содержание VSB2-605