9
Programming Instructions
TIME OF DAY, YEAR,
MONTH, DAY,
Time of day is for normal op-
eration of system and the
scheduling of the regenera-
tion time. The date is used
in a diagnostic function to
track the last time the sys-
tem regenerated.
SET HARDNESS
This value is the maximum
compensated water hardness
in grains per gallon of the
raw water supply. It is used
to calculate the system ca-
pacity. If Ferrous Iron is pre-
sent add 4 gpg for every 1
ppm of Ferrous Iron.
SET PEOPLE
This value is the number of
people living in the home. It
is used to calculate the
amount of water needed for
daily use and the reserve ca-
pacity of the system.
SALT SETTING
There are 3 settings to
choose in the MENU SET-
TINGS. These settings will
determine the salt dosage
and capacity for the system.
For SIM units choose IRON &
MN.
WATER TYPE
Select WELL / OTHER if any
Iron or Manganese is present
or if the water source is not
clean (< 1NUT turbidity).
The system will back wash
every time.
REGEN TIME
This setting determines the
time of day to perform a
scheduled regeneration.
REGEN DAYS
This value is the number of
days between regenerations
or back washes to clean the
filters.
GALLONS
Default value is OFF. Adjust
the GALLONS to set the ca-
pacity. This will cause the
unit to regenerate either
when the gallons remaining
goes to zero or the days be-
tween regeneration is zero.
Which ever occurs first.
Содержание 15100300
Страница 7: ...7 Installation...
Страница 17: ...17 Main Repair Parts Connectors A A A B D F E A C...
Страница 19: ...19 Control Valve Parts List...
Страница 20: ...20 Power Head Exploded View...
Страница 21: ...21 Power Head Parts List...
Страница 22: ...22 Trouble Shooting...