Failure 

– remedial action 

 
General: 
 
If there is no display or should no sign for any operation be visible, initially check the following: 
 
Check whether or not the unit is switched on and mains voltage 230V/50 cps available. If that is 
all correct, check the fuse as per the below instruction: 
 
The fuse is provided in the terminal unit on the ledge for the water part connections and mains 
supply. Please take care that the mains plug is removed prior to opening the unit! Open the lower 
front cover and replace fine fuse (3.15 AT). 
 
 
 
 
 
 
 
 
 
 
 
 
 

If there is still no LED scale visible, inform the technical department of Hydrotec.  

 
 
Failure 1: 

Undercurrent 

Check connection and correct fit of Harting coupling.  
 
 
Failure 2: 

Overload 

Failure at magnet coil in water unit. Inform Hydrotec immediately in that case since there are no 
further local steps possible.  
The first time the failure had been recognised must be noted.  
Disconnect unit from mains voltage 
 
 
Failure 3: 

Short cut 

Short cut (external) of coil circuit 
Disconnect unit from mains supply. Check for foreign particles in connection (spiral cable of con-
trol box and connection socket of water unit).  
Restart unit. Hydrotec have to be informed immediately if the failure arises again. There are no 
further local measures necessary. Disconnect the unit from mains supply.  
 
 
Failure 4: 

Control box 

Faulty control box. Return box for inspection to Hydrotec along with corresponding failure report 
or other information.  

 

Supply conditioning unit 

Supply main voltage 

Voltage free contact 

Fuse 3,15 AT 

Содержание HY-MAG Competition

Страница 1: ...1 Operating Instruction HY MAG Competition Serial number _______________ HYDROTEC Hydrotec House 4 5 Manor Courtyard Hughenden Avenue High Wycombe HP13 5RE Tel 01494 796040 Fax 01494 796049...

Страница 2: ...trol operations the plastic cover must be opened with the right hand closure Once setting has been finished the glass must be closed again with an audible noise Initiating phase Once the control box w...

Страница 3: ...t ratings for the corresponding HY MAG types are shown in the below list REFIT Phase Duration about 2 s magnetic remanence clear ing LED extinguishes successively to the left within 2 seconds GREEN LE...

Страница 4: ...Retrieval of individual menu sequences confirmation acknowedge ment of settings NOTE The monitoring returns to Standard Mode if input is delayed for more than 30 sec onds and standard operation is sho...

Страница 5: ...can be selected by pressing the buttons and the correct mode then be confirmed and acknowledged by pressing the button once The control box and or monitoring returns automatically to main menu after...

Страница 6: ...ed whereby the display shows the actual setting If the setting is to be altered press the button and should no modification be requested the sub menu can be left by pressing the button The active fiel...

Страница 7: ...h a line underneath Once the correct setting is achieved the button must be pressed until the line underneath is no longer visible If the total switch settings for the selected and retrieved group of...

Страница 8: ...ttons or Once the correct language is shown confirm by pressing the button and the setting is finished Service The service menu is code protected and can be retrieved from authorised service personnel...

Страница 9: ...AC max breaking capacity 1500W class AC1 Ohm load max breaking capacity 300W class AC15 electro magnetic load min breaking capacity 500mW 12V 10mA Failure 1 Undercurrent Coil not closed faulty connect...

Страница 10: ...rrect fit of Harting coupling Failure 2 Overload Failure at magnet coil in water unit Inform Hydrotec immediately in that case since there are no further local steps possible The first time the failur...

Отзывы: