background image

 
 

 

- 7 - 

Time zones 

 
The switch-on and 

–off times of the unit can be programmed in the menu ‘Time zones’ after the 

operation mode 

‘Timer control’ was retrieved. One such setting is possible per day.  

 
A group of several days or also individual days can be programmed by the operator. Switch-on 
and switch-off times are controlled and initiated by the internal timer.  
 
Groups: 

 

Mo ... Su 

(several days) 
 
 
 

 

 

Mo ... Fr 

 
 
 
 

 

 

Sa ... Su 

 
 
 
Individual days: 

Mo, Tue, Wed, Thu, Fr, Sa, Su 

 
 

 

 

 

 

 

 

    and so on 

– for every day in the week. 

 
 

An initial selection of the desired  menu is possible with the Cursor buttons 

 , the menu 

is then retrieved by pressing the button 

 once and the switching times can then be altered 

with the Cursor buttons. The figure that can actually be altered is marked with a line underneath. 

Once the correct setting is achieved, the button  

 must be pressed until the line underneath 

is no longer visible. If the total switch settings for the selected and retrieved group of days /indi-

vidual day are to be cleared, press the button  

 once.  

 
The times for switch-on and switch-off can be selected right on the dot. Below is an example for 
setting switch time - group of days Mo-Su, switch-on 6.00 a.m., switch-off 10.00 p.m.  
 
 
 
 
NOTE: 

If times different to the individual days than provided in the corresponding group of 
days are set, the display for the group of days show **:**-**:** and the actual switch 
time is set in the day monitoring.  

 
 

If the switch-off time is set earlier than the switch-on time or if the times were reset 
(00:00-00:00), the water conditioning unit is not activated that day(s).  

 
 
 

Select time zone:

 

Mo .. Su:      **:** - **:** 

Select time zone:

 

Mo .. Fr:      **:** - **:** 

Select time zone:

 

Sa .. Su:      **:** - **:** 

Select time zone:

 

Mo:           **:** - **:** 

Alter time zone:

 

Mo .. Su:      06:00 - 22:00 

Содержание HY-MAG Competition

Страница 1: ...1 Operating Instruction HY MAG Competition Serial number _______________ HYDROTEC Hydrotec House 4 5 Manor Courtyard Hughenden Avenue High Wycombe HP13 5RE Tel 01494 796040 Fax 01494 796049...

Страница 2: ...trol operations the plastic cover must be opened with the right hand closure Once setting has been finished the glass must be closed again with an audible noise Initiating phase Once the control box w...

Страница 3: ...t ratings for the corresponding HY MAG types are shown in the below list REFIT Phase Duration about 2 s magnetic remanence clear ing LED extinguishes successively to the left within 2 seconds GREEN LE...

Страница 4: ...Retrieval of individual menu sequences confirmation acknowedge ment of settings NOTE The monitoring returns to Standard Mode if input is delayed for more than 30 sec onds and standard operation is sho...

Страница 5: ...can be selected by pressing the buttons and the correct mode then be confirmed and acknowledged by pressing the button once The control box and or monitoring returns automatically to main menu after...

Страница 6: ...ed whereby the display shows the actual setting If the setting is to be altered press the button and should no modification be requested the sub menu can be left by pressing the button The active fiel...

Страница 7: ...h a line underneath Once the correct setting is achieved the button must be pressed until the line underneath is no longer visible If the total switch settings for the selected and retrieved group of...

Страница 8: ...ttons or Once the correct language is shown confirm by pressing the button and the setting is finished Service The service menu is code protected and can be retrieved from authorised service personnel...

Страница 9: ...AC max breaking capacity 1500W class AC1 Ohm load max breaking capacity 300W class AC15 electro magnetic load min breaking capacity 500mW 12V 10mA Failure 1 Undercurrent Coil not closed faulty connect...

Страница 10: ...rrect fit of Harting coupling Failure 2 Overload Failure at magnet coil in water unit Inform Hydrotec immediately in that case since there are no further local steps possible The first time the failur...

Отзывы: