Page 23
autocut 5-32cts user manual edItIon II 2015-01-16
Page 24
autocut 5-32cts user manual edItIon II 2015-01-16
5.6.1 Article
this menu work as an initial setup window with possibility to save all parameters to
the data base memory.
1. Article No:
name of the loaded and saved recipe, if any parameter is changed
from the original recipe the text ”Recipe not saved” will appear.
2. Hose-type:
Name field for any extra information.
3. Length:
requested length in mm.
4. SPC-test:
the machine will pause cutting and the operator can perform a statistic
process control when this chosen amount is fulfilled.
When the sequence has paused the indicator lamp will flash and a text ”SPC-test” will
appear in the green ”Order”menu and when the test is done, continue the cutting with the
”Cycle start” button.
5. Corr +/-:
correction of the hose length in mm. If achived hose length doesn’t match
requested length a correction, plus or minus, can be set.
6. Toler.:
tolerances for the length alarm, exceeding the set value will generate an alarm.
7. Measuring Wheel dia.:
diameter for the measuring wheel (only for length control)
Adjust Ø value if ”Ext. Current Length” doesn’t match ”Requested Length”
found in the ”Length control”menu.
HYDROSCAND MACHINE AB
Kungsvägen 22
Phone: +46 (0)225 - 573 30
S-783 35 Säter
Fax:
+46 (0)225 - 501 08
Sweden
Web:
www.hydroscand-machine.se
Edition 7-00
MANUAL-E
Page 13
This menu work as an initial setup window with possibility to save all parameters to
the data base memory.
1.
Article No:
Name of the loaded and saved recipe, if any parameter is changed
from the original recipe the text "Recipe not saved" will appear.
2.
Hose-type:
Name field for any extra information.
3.
Length:
Requested length in mm.
4.
SPC-test:
The machine will pause cutting and the operator can perform a
statistic process control when this chosen amount is fulfilled.
When the sequence has paused the indicator lamp will flash and a text "SPC-test" will
appear in the green "Order" menu and when the test is done, continue the cutting with the
"Cycle start" button.
5.
Corr +/-:
Correction of the hose length in mm. If achived hose length doesn't match
requested length a correction, plus or minus, can be set.
6.
Toler.:
Tolerances for the length alarm, exceeding the set value will generate an alarm.
7.
Measuring Wheel Dia.:
Diameter for the measuring wheel (only for length control)
Adjust Ø value if "Ext. Current Length" doesn't match "Requested Length"
found in the "Length control" menu.
Continue on next page
7.20 Article-Recipe
1
2
3
4
5
6
7
13
8
9
10
11
12
19
18
17
16
15
14