1 -
Prior to testing your installation for leaks, you
must
properly bond the Whirlpool Bath Heater to the
bonding system of your hydromassage bathtub (see Fig. 26). All Whirlpool Bath Heaters come
equipped with a bonding lug
and 8AWG bonding wire specifically for this purpose. Refer to bathtub
manufacturers instructions to locate the bonding system. All electrical wiring and bonding must be
done as specified in Article 680, National Electric Code and your local Building Code.
8AWG Bonding Wire
(Included with your heater - *May Be on Bottom of Tube*)
To Bathtub
Bonding System
BONDING YOUR HEATER
Bonding Lug
Fig. 26
7” Inline Shown
SINGLE CIRCUIT INSTALLATION**
In certain cases you may be able to plug the heater and the pump into the same single circuit outlet. This
generally requires that one or both of the components have a very low amperage rating. See the chart
below to determine if your components are sized to allow this type of installation.
If your heater
amps are . . .
AND
AND
AND
THEN
THEN
THEN
Your pump amps
are less than. . .
10.6A
7.7A
3.5A
You can use a single
circuit this size
20A
20A
20A
5.4A
8.3A
12.5A
(650W)
(1000W)
(1500W)
ELECTRICAL
PANEL
ONE (1) SHARED CIRCUIT
RESET
TEST
15A / 115V
OR
20A / 115V
BRANCH CIRCUIT
**Single circuit installation does not apply to 240V heaters.