1 -

 

Power to the hydromassage bathtub must be turned OFF

 and all water must be drained from 

the bathtub before proceeding. 

2 -

 Locate the

 

hydromassage jet pump and “vacuum” plumbing in the system. Remember, the water 

enters the pump through the front or “vacuum” side and exits through the top or “pressure” side. 

Fig. 20

9

VACUUM INSTALLATION

No Heater Ready Fitting

CUT HERE

Template located on 
back page. 

Cut and 

detach

-UV SERIES

VACUUM

3 -

 Choose a location for your Pure Heat heater close to the hydromassage jet pump, ensuring there is

 

at 

least 2-1/2” of

 

plumbing left on each side of the cuts

 

to install the tailpieces. For convenience, a

 

template has been

 

provided on the back page of this instruction booklet. Simply detach, position 

against plumbing and mark according to plumbing size (see Fig. 20).

4 -

 Using a hacksaw, PVC cutter or a cable saw, cut the pipe at the marks made. If using a cable saw, 

carefully line the saw blade up with the marks that were made in the previous step and begin cutting 
using an alternating pulling/releasing motion (see Fig. 21). Once successfully cut away, discard the   
detached portion of plumbing.

Fig. 21

5 -

 De-burr

 

the plumbing, clean outer surface of plumbing and prepare the surfaces for gluing. 

6 -

 Your Pure Heat heater includes three (3) sets of tailpieces

 

(1 set for 2” plumbing) to adapt the heater to 

virtually any hydromassage bathtubs plumbing system. Dry fit the tail pieces to determine

 

which 

tailpieces adapt properly to your plumbing and discard the tailpieces that do not fit. 

  

 

Note: Let the saw blade do the 
work, do not put excess pressure 
on the plumbing. Have someone 
else stabilize the plumbing while 
you cut if needed.  

www.bathheaters.com

Содержание Pure Heat PH101-10UP

Страница 1: ...Only this set of tailpieces with PH301 15UP V This Manual Covers Fig 1 A B C D F G TM E PRESSURE MODELS 5 1 2 Models PH101 15UP S 120V 1500W 7 Models PH101 15UP 120V 1500W PH101 10UP 120V 1000W PH101...

Страница 2: ...s hydromassage bathtub Disconnect this hydromassage bathtub and have the problem corrected by a qualified service representative before using 3 SAVE THESE INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS Pr...

Страница 3: ...e to flat sealing surface Refers to removing excess plastic that may have built up during the cutting process A heater that can be installed directly inline in the existing plumbing system of a hydrom...

Страница 4: ...te these instructions do not cover the Tee Style hydromassage bathtub heater Fig 2 INLINE HEATER TEE HEATER 3 VACUUM MODELS PRESSURE MODELS HEATER READY HEATER READY HEATER READY PROCEED TO PAGE 5 Fig...

Страница 5: ...heater Be sure you choose a location that will be accessible if a need for service should arise The model of Pure Heat heater pressure vs vacuum is clearly marked on the outside of the carton This wil...

Страница 6: ...en space where the Heater Ready fitting was located ensure that the gaskets remain in place Slide both heater nuts inward toward the center of the heater to expose the mating surfaces of the heater ho...

Страница 7: ...are now ready to install the heater in the open space where the Heater Ready fitting was located ensure that the gaskets remain in place Slide both heater nuts inward toward the center of the heater...

Страница 8: ...rks made If using a cable saw carefully line the saw blade up with the marks that were made in the previous step and begin cutting using an alternating pulling releasing motion see Fig 15 Once success...

Страница 9: ...l your Pure Heat heater Fig 17 Fig 16 8 Remove two 2 heater gaskets included with your Pure Heat heater and install them onto the plumbing tailpieces making sure the gasket ridge is seated in the tail...

Страница 10: ...plumbing and mark according to plumbing size see Fig 20 4 Using a hacksaw PVC cutter or a cable saw cut the pipe at the marks made If using a cable saw carefully line the saw blade up with the marks...

Страница 11: ...the nuts can crack see Fig 25 Fig 25 CONTINUE ON TO PAGE 12 BONDING YOUR HEATER UV SERIES VACUUM Wwww bathheaters com 7 OR 5 1 2 7 You are now ready to install the tailpieces onto the bathtub plumbin...

Страница 12: ...ATED CIRCUIT This means no other appliances or lights can be on this circuit Refer to equipment data label for power supply requirements of your bath heater Use copper conductors ONLY The ground must...

Страница 13: ...ub Bonding System BONDING YOUR HEATER Bonding Lug Fig 26 7 Inline Shown SINGLE CIRCUIT INSTALLATION In certain cases you may be able to plug the heater and the pump into the same single circuit outlet...

Страница 14: ...UB IMMEDIATELY IF A LEAK IS DETECTED AND CORRECT THE PROBLEM BEFORE RETESTING 9 If no leaks were detected a PRESSURE leak test must be performed Perform this final REQUIRED leak test by activating the...

Страница 15: ...ter Wiring Error Replace Heater OVERHEAT PROTECTION TRIPPED Water Blockage Correct Remove Blockage Low Water Flow Correct Problem High Limit Will Not Reset Replace Heater WATER LEAKS FROM CONTROL BOX...

Страница 16: ...reinstallation of the warrantable product is bourn by the purchaser The purchaser s sole remedy will be the repair or replacement of the manufacturer s product Any products which are claimed to be de...

Страница 17: ...16 Wwww bathheaters com Fig A Mark PVC cut area Note Identify you heater by part number Fig B Mark PVC cut area 7 Heater Part numbers PH101 15UP V PH101 10UP V PH101 65UP V PH301 15UP V PH203 20UP V...

Страница 18: ...5UV PH301 15UP PH301 15UV PH203 20UP PH203 20UV Use this template as a guide when making cuts during Whirlpool Bath heater installation Cut and detach from instructions Determine the length of the hea...

Страница 19: ...5UV S Use this template as a guide when making cuts during Whirlpool Bath heater installation Cut and detach from instructions Determine the length of the heater Lay template on PVC plumbing See page...

Страница 20: ...85 0049PH REV 8 05 14 510A N Sheridan St Corona CA 92880 Email info bathheaters com Internet http www bathheaters com Telephone 951 273 7575 Fax 800 332 7190 TM...

Отзывы: