26
Troubleshooting:
Problem / Situation
Area
Possible cause
Possible Solution
TK MO FM RM MP OT
Tank system leaks
water
●
Leak from bottom fitting,
check if bottom fitting was
not installed correctly to
thread damage
Re-install or replace new
bottom fitting set with
Teflon tape. Do not reuse
Teflon tape
●
Leak from bottom fitting of
outlet port, check if bottom
fitting was missing O-Ring
or O-Ring damage
Replace O-Ring with
grease, check the O-Ring
is in place, is clean and is
intact
●
Leak from bottom fitting of
outlet port, check if bottom
fitting was missing collect
or retainer damage
Replace new bottom fitting
unit. Rewrap thread
connections with new
Teflon tape
●
Leak from top fitting,
check if top fitting was not
installed correctly or
thread damage
Re-install or replace new
top fitting set or connector
with Teflon tape. Do not
reuse Teflon tape.
●
Leak from conductivity
sensor, check if the
sensor was not installed
correctly or thread
damage
Re-install or replace
conductivity sensor set with
Teflon tape
●
Leak from air relief valve,
check if the valve was not
installed correctly or
thread damage
Re-installation or replace
air relief valve with Teflon
tape
Module leaks water
●
Leak form in/outlet port,
check if the O-Ring was
not on the position or
damage or deformation or
particle on the surface
Replace O-Ring with
grease, check the O-Ring
is in place, is clean and is
intact
●
Leak from outside die-
casting, check if the
torque of bolt was not
correctly
Re-install the module and
tighten front lid
●
Leak from outside die-
casting, check if the radial
seal was damaged or not
on the correctly position
Replace O-Ring with
grease, check the O-Ring
is in place, is clean and is
intact
●
Leak from outside die-
casting, check if there are
any creak on the die-
casting component
Replace Die-Casting part if
necessary
Front Manifold leaks
water
●
Leak form the connection
port, check if the sealing
O-Ring was twisted or
damage
Replace O-Ring with
grease, check the O-Ring
is in place, is clean and is
intact
●
Leak form the Manifold
body, check if there are
any crack on the where
are the water coming
Change Front Manifold