Product Specifications:
Item
Unit
Model#
Hydronovation
WP1
Product Flow Rates
Minimum
gpm
NA
Normal
gpm
NA
Maximum at full tank,
(depends on pressure)
gpm
NA
Typical Recovery
%
75
Minimum Operating Pressure
Processor
psi
40
Maximum Operating Pressure
Processor
psi
85
Maximum Pressure Drop
Cassette
psi
4
Feed Water Temperature Range
Processor
F
⁰
35-100
Cell Processing Time
From feed to product water
GPH
30
Power Supply Characteristics
DC Voltage
V
24
DC Amperage
A
5A/2.5A
Power supply
watts
350
Power at peak consumption
watts
250
Power at standby mode
watts
5
Input AC Voltage
VAC
115/230@
50/60Hz
Daily Energy Consumption
300 gpd @ 10hr
kwh
2.5
Efficiency
%
85
Ionized substances removed by
cassette
Cations
Sodium
%
70
Calcium
%
80
Magnesium
%
80
Anions
Chlorides
%
80
Sulfates
%
80
Bicarbonate
%
80
Nitrates
%
80
Others
Arsenic
ppb
10
Ionized Organics
TDS reduction
All
%
75-80
IMPROTANCE:
Weakly ionized substances such as silica and carbon dioxide are not removed. Particles,
Organics, Bacteria and Pyrogens, any more than that.
Appendix