background image

4

370 Encinal Street, 

Suite 1

50

Santa Cruz, Ca  9506

0

P: 888-426-5644 / F: 831-336-9840
www.

hydrologicsystems.com

This system has been designed for installa

ti

  on by a licensed professional such as a contractor or plumber.  Proper comple

ti

  on of this 

installa

ti

  on will require basic familiarity with standard sink plumbing and proper use of common hand and power tools.  Improperly 

installed systems could result in water damage due to leaks or 

fl

 ooding.  Do not use with water that is microbiologically unsafe.

System Speci

fi

 ca

ti

 ons

  

Membrane 

System 

w/Tank

   

 

Pressure 

40-80 psi (275 kPa - 552 kPa) 

Temp 

40°F - 100°F (4°C - 38°C)

TDS <2000 

mg/L

Chlorine <1.0 

mg/L

Turbidity <1 

NTU

SDI  

<5

pH 4-8

Performance Speci

fi

 ca

ti

 ons

 

 

 

Feed water must be potable, municipal water.  Must 
be free of poten

ti

 al membrane foulants such as Iron, 

Hydrogen Sul

fi

 de and Manganese.

 Produc

ti

 on 

40 GPD  

21.6 GPD 

   

(151 LPD) 

(81.8 LPD)

 TDS 

Rejec

ti

 on 

95% 

95%

 Recovery

1

 26.3%  17%

  Brine to Product 

2.8:1 

4.86:1

1

 The percentage of the feed water available as reverse osmosis treated 

water under normal opera

ti

 ng condi

ti

 ons.

Tested at 60 psig (4 bar), 500ppm TDS municipal water, 77°F (25°C)

Feed Water Requirements

System - 9.72” W x 13.75” D x 15.38” H ( 24.7 x 34.9 x 39.1 cm), 11 lbs. (5 kg.)
Shipping Box - 14.5"L x 11.25"W x 20"H (36.8 x 28.6 x 50.8 cm), 13.7 lbs. (6.2 kg.)

Dimensions and Weight

A.  Product water storage tank
B. Tank 

valve

C.  Tank tubing (3/8” white)
D. Air-gap 

faucet

E. Drain 

connec

ti

 on assembly

F.  Drain tubing (3/8” white)
G. Quick 

connect 

fi

 

tti

  ng

H.  Drain tubing (1/4” black)
I.  Faucet tubing (3/8” blue)
J.  Four-stage desalinator cartridge 
K.  Feed water tubing (1/4” green)
L. Inlet 

fi

 

tti

  ng with shut-o

 

M.  GAC and remineraliza

ti

 on post-

fi

 lter

A

B

)

E

F

G

D

K

L

M

I

H

C

 (not shown)

(behind cover)

Содержание ecospring

Страница 1: ...uite 103 Santa Cruz Ca 95065 P 888 426 5644 F 831 336 9840 www eco spring com 02 09 Installation Guide Owner s Manual 350 Encinal Street Suite 170 Santa Cruz Ca 95060 P 888 426 5644 F 831 336 9840 www...

Страница 2: ...d water quality These cartridges work together to remove potential contaminants from your tap water and must be replaced every 6 12 months Any significant change in performance of the system should be...

Страница 3: ...damage to the unit due to fire accident negligence act of God or events beyond the control of the Manufacturer are not covered by this warranty Incidental and Consequential Damages The Manufacturer do...

Страница 4: ...e of potential membrane foulants such as Iron Hydrogen Sulfide and Manganese Production 40 GPD 21 6 GPD 151 LPD 81 8 LPD TDS Rejection 95 95 Recovery1 26 3 17 Brine to Product 2 8 1 4 86 1 1 The perce...

Страница 5: ...plastic spacer 2 open end up onto the threaded faucet stem 7 Loosely thread the 3 8 washer 3 and mounting lock nut 4 onto the threaded stem 8 Thread faucet quick connect adapter 5 on to threads of fa...

Страница 6: ...g nut securely 6 Attach the small feed valve warning tag from the parts bag to the feed valve 7 Attach the Shuto Warning label to the system so that it is directly visible Fill out the Date of Install...

Страница 7: ...lorinating agent in order to ensure tank internal cleanliness Also the carbon filter cartridge will release a small amount of carbon fines during the first tankful of flow This flushing procedure will...

Страница 8: ...rs Press top or bottom of cartridge to engage connectors until it snaps into place properly 4 All tubing connections especially push in quick connections are fully inserted 5 Tubing connected between...

Страница 9: ...ly install the retaining clip will result in accidental leaks and flooding 7 Turn on feed water shut o valve and open dispensing faucet 8 Close dispensing faucet after water starts running 9 Observe s...

Отзывы: